October 18, 2025Frontiers in Cardiovascular Medicine0 citationsOpen Access

ECG-XPLAIM: eXPlainable Locally-adaptive Artificial Intelligence Model for arrhythmia detection from large-scale electrocardiogram data

View Full Paper
PPPanteleimon PantelidisSRSamuel Ruipérez-CampilloJVJulia E. Vogt

Key Points

  • ECG-XPLAIM achieved high diagnostic performance with AUROC values exceeding 0.9 in arrhythmia detection.
  • External validation on PTB-XL showed exceptional performance for AFib and STach, exceeding sensitivity of 0.95.
  • Grad-CAM visualization revealed ECG features influencing model predictions, enhancing interpretability and clinical relevance.
  • The open-source release of ECG-XPLAIM promotes broader application and future improvements in ECG analysis.

Abstract

Background Timely and accurate detection of arrhythmias from electrocardiograms (ECGs) is crucial for improving patient outcomes. While artificial intelligence (AI)-based ECG classification has shown promising results, limited transparency and interpretability often impede clinical adoption. Methods We present ECG-XPLAIM, a novel deep learning model dedicated to ECG classification that employs a one-dimensional inception-style convolutional architecture to capture local waveform features (e.g., waves and intervals) and global rhythm patterns. To enhance interpretability, we integrate Grad-CAM visualization, highlighting key waveform segments that drive the model's predictions. ECG-XPLAIM was trained on the MIMIC-IV dataset and externally validated on PTB-XL for multiple arrhythmias, including atrial fibrillation (AFib), sinus tachycardia (STach), conduction disturbances (RBBB, LBBB, LAFB), long QT (LQT), Wolff-Parkinson-White (WPW) pattern, and paced rhythm detection. We evaluated performance using sensitivity, specificity, and area under the receiver operating characteristic curve (AUROC), and benchmarked against a simplified convolutional neural network, a two-layer gated recurrent unit (GRU), and an external, pre-trained, ResNet-based model. Results Internally (MIMIC-IV), ECG-XPLAIM achieved high diagnostic performance (sensitivity, specificity, AUROC 0.9) across most tasks. External evaluation (PTB-XL) confirmed generalizability, with metric values exceeding 0.95 for AFib and STach. For conduction disturbances, macro-averaged sensitivity reached 0.90, specificity 0.95, and AUROC 0.98. Performance for LQT, WPW, and pacing rhythm detection was 0.691/0.864/0.878, 0.773/0.973/0.895, and 0.96/0.988/0.993 (sensitivity/specificity/AUROC), respectively. Compared to baseline models, ECG-XPLAIM offered superior performance across most tests, and improved sensitivity over the external ResNet-based model, albeit at the cost of specificity. Grad-CAM revealed physiologically relevant ECG segments influencing predictions and highlighted patterns of potential misclassification. Conclusion ECG-XPLAIM combines high diagnostic performance with interpretability, addressing a key limitation in AI-driven ECG analysis. The open-source release of ECG-XPLAIM's architecture and pre-trained weights encourages broader adoption, external validation, and further refinement for diverse clinical applications.