PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
October 18, 2025Atmospheric measurement techniques0 citationsOpen Access

Performance evaluation of multi-source methane emission quantification models using fixed-point continuous monitoring systems

View Full Paper
DBDavid J. BallUIUmair IsmailNENathan Eichenlaub

Key Points

  • Results indicate that the Puff model reduces bias and error variance, enhancing methane emissions localization.
  • The Puff MCMC approach achieves the best performance, surpassing the accuracy of the least-squares fitting framework.
  • The integration of long-term data is crucial for accurate estimates of total methane emissions over time.
  • Findings aid facility-level emissions risk assessment and improve overall greenhouse gas inventory accuracy.

Abstract

Abstract. Quantifying methane emissions from oil and gas facilities is crucial for emissions management and accurate facility-level greenhouse gas (GHG) inventory development. This paper evaluates the performance of several multi-source methane emission quantification models using the data collected by fixed-point continuous monitoring systems as part of a controlled-release experiment. Two dispersion modeling approaches (Gaussian plume, Gaussian puff) and two inversion frameworks (least-squares optimization and Markov chain Monte Carlo) are applied to the measurement data. In addition, a subset of experiments are selected to showcase the application of computational fluid dynamics (CFD) informed calculations for direct solution of the advection–diffusion equation. This solution utilizes a three-dimensional wind field informed by solving the momentum equation with the appropriate external forcing to match on-site wind measurements. Results show that the Puff model, driven by high-frequency wind data, significantly improves localization and reduces bias and error variance compared to the Plume model. The Markov chain Monte Carlo (MCMC)-based inversion framework further enhances accuracy over least-squares fitting, with the Puff MCMC approach showing the best performance. The study highlights the importance of long-term integration for accurate total mass emission estimates and the detection of anomalous emission patterns. The findings of this study can help improve emissions management strategies, aid in facility-level emissions risk assessment, and enhance the accuracy of greenhouse gas inventories.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Ball et al. (2025) studied this question.

synapsesocial.com/papers/68f408995de60f8893c6fdf8https://doi.org/10.5194/amt-18-5375-2025
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Charting the Course: The National Petroleum Council’s Advice on the Role of Emission Detection and Quantification in Reducing Greenhouse Gas Emissions from the U.S. Natural Gas Supply Chain2024 · 2 citations
  2. 2Estimating methane emission durations using continuous monitoring systems2024 · 1 citations
  3. 3Performance Evaluation of Fixed-Point Continuous Monitoring Systems: Influence of Averaging Time in Complex Emission Environments2025 · 4 citations
  4. 4Estimating Total Methane Emissions from the Denver-Julesburg Basin Using Bottom-Up Approaches2024 · 6 citations