December 4, 2025The International Journal of Cardiovascular Imaging0 citationsOpen Access

Multimo dality assessment of aortic valve area in aortic stenosis: a multicenter validation study

View Full Paper
JSJ. Studier-FischerSGSunaina von GarlenSPSven M. Piepenburg

Key Points

  • A correlation is established between transthoracic echocardiography and computed tomography angiography in assessing aortic stenosis.
  • Mean aortic valve area measured by computed tomography was 0.96 cm², indicating high interrater reliability (IRR = 0.84) with echocardiography.
  • Retrospective analysis of 176 patients assessed the thresholds for diagnosing severe aortic stenosis using ROC analysis.
  • Findings support the use of non-invasive computed tomography as a reliable method for determining aortic stenosis severity, confirming diagnostic thresholds.

Abstract

Abstract Objectives Transthoracic echocardiography (TTE) is the standard modality for grading aortic stenosis (AS) severity. Transesophageal echocardiography (TOE) allows direct aortic valve area (AVA) planimetry (AVA TOE ), while computed tomography angiography (CTA) offers a non-invasive alternative (AVA CTA ). This study aimed to evaluate the correlation between AVA measurements across modalities and to determine a diagnostic AVA CTA threshold for severe AS. Methods This retrospective study included a single-center derivation cohort of 176 patients (mean age 80.0 ± 7.7 years, 52.8% male) with moderate to severe AS who underwent full-cycle CTA, TTE, and TOE. AVA CTA was measured by two independent raters. Correlation with AVA TOE and other parameters was assessed. Receiver operating characteristic (ROC) analysis was used to define an optimal AVA CTA threshold for severe AS, which was validated in a multi-center cohort of 407 patients (mean age 80.9 ± 6.7 years, 52.8% male) with comparable characteristics. Results Mean AVA CTA was 0.96 ± 0.28 cm² with a high interrater reliability (IRR = 0.84), compared to a mean AVA TOE of 0.88 ± 0.26 cm² (Pearson’s r = 0.73). ROC analysis identified 0.96 cm² as the optimal AVA CTA threshold for diagnosing severe AS (AUC = 0.846; sensitivity = 71.7%; specificity = 89.8%) compared to TOE grading. This threshold yielded good diagnostic performance in the validation cohort (AUC = 0.817; sensitivity = 78.2%; specificity = 72.6%). Conclusions AVA CTA demonstrated high reliability, showing a strong correlation with AVA TOE . The 0.96 cm² threshold, defined in the derivation cohort, performed well in the validation cohort for assessing aortic stenosis severity.