PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
December 5, 2025Frontiers in Neurorobotics4 citationsOpen Access

IAP-TransUNet: integration of the attention mechanism and pyramid pooling for medical image segmentation

View Full Paper
SZShuting ZhaoXCXinrong Chen

Key Points

  • Achieved Hausdorff distance reduction by 2.92% for multi organ segmentation tasks.
  • Utilized attention mechanism to enhance feature extraction for medical image segmentation.
  • Methodology includes a lightweight network using depthwise separable convolution for efficiency.
  • Results indicate strong performance with potential for generalization across CT and MRI imaging modalities.

Abstract

Introduction The combination of CNN and Transformer has attracted much attention for medical image segmentation due to its superior performance at present. However, the segmentation performance is affected by limitations such as the local receptive field and static weights of CNN convolution operations, as well as insufficient information exchange between Transformer local regions. Methods To address these issues, an integrated attention mechanism and pyramid pooling network is proposed in this paper. Firstly, an efficient channel attention mechanism is embedded into CNN to extract more comprehensive image features. Then, CBAMASPP module is introduced into the bottleneck layer to obtain multi-scale context information. Finally, in order to address the limitations of traditional convolution, depthwise separable convolution is used to achieve a lightweight network. Results The experiments based on the Synapse multi organ segmentation dataset and ACDC dataset showed that the proposed IAP-TransUNet achieved Dice similarity coefficients (DSCs) of 78. 85% and 90. 46%, respectively. Compared with the state-of-the-art method, for the Synapse multi organ segmentation dataset, the Hausdorff distance was reduced by 2. 92%. For the ACDC dataset, the segmentation accuracy of the left ventricle, myocardium, and right ventricle was improved by 0. 14%, 1. 89%, and 0. 23%, respectively. Discussion The experimental results demonstrate that the proposed network has improved the effectiveness and shows strong performance on both CT and MRI data, which suggests its potential for generalization across different medical imaging modalities.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Zhao et al. (2025) studied this question.

synapsesocial.com/papers/693231118e51979591dcdfbfhttps://doi.org/10.3389/fnbot.2025.1706626
Ask AI
Helpful
Bookmark
Share
View Full Paper