Study of Bremsstrahlung X‐Rays Emitted During Monoenergetic and Spread‐Out Bragg Peak Proton Irradiations in Preclinical Conditions

View Full Paper
MEManon EvinSCSophie ChiavassaCKCharbel Koumeir

Key Points

  • More than 1000 X-rays/Gy detected during preclinical proton irradiation, indicating significant bremsstrahlung emissions.
  • The absorbed dose at fixed positions in the Bragg plateau was determined with < 1.5% accuracy at 1 Gy for both beams.
  • Assessment using a spectrometer and collimator detected distinct energy spectrum features of X-rays emitted.
  • Bremsstrahlung X-rays may enable real-time monitoring of irradiation effects in small animal models in future studies.

Abstract

ABSTRACT Hadrontherapy treatments generally take advantage of the finite path of the ions in matter to limit healthy tissue irradiation. The absence of a transmitted beam, however, complicates the online assessment of the targeting. This verification becomes even more crucial with low‐energy ion beams used for small animal preclinical irradiations, easily disrupted by changes in the tissues or in the position of the animal, and when comparing different irradiation techniques, such as irradiation in the Bragg plateau of a monoenergetic beam and irradiation in the spread‐out Bragg peak (SOBP). The bremsstrahlung X‐rays emitted during irradiation by a 68 MeV proton beam were studied along a mouse‐sized cylindrical phantom on a realistic beamline, including a ridge filter allowing passive shaping of the SOBP. A compact semiconductor spectrometer was positioned orthogonally to the beam propagation direction. The detector's field of view was controlled using a 2 mm diameter collimator fixed on a tailored tungsten shield. More than 1000 X‐rays/Gy were detected, even in the Bragg peak regions for both monoenergetic and SOBP beams. The absorbed dose at a fixed position in the Bragg curve's plateau can be accurately determined (< 1.5% at 1 Gy) using X‐ray energy spectrum integrals. Furthermore, partial integral ratios, X‐ray average energy and X‐ray energy at the maximum amplitude of the spectrum showed a similar variation with proton mean energy in the field of view for both modalities. Bremsstrahlung X‐rays are a promising probe to monitor in real time the irradiation of small animals at preclinical absorbed doses.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Evin et al. (2025) studied this question.

synapsesocial.com/papers/693624ba4fa91c937236c830https://doi.org/10.1002/xrs.70063