PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
December 8, 2025Fire3 citationsOpen Access

Study on the Effectiveness of Perfluorohexanone in Extinguishing Small-Scale Pool Fires in Enclosed Compartments Under Low-Pressure Conditions

View Full Paper
QLQuanyi LiuPZPei Zhu

Key Points

  • This study investigates the fire suppression effectiveness of perfluorohexanone under low-pressure conditions.
  • Utilized a self-built fire suppression experimental platform.
  • Analyzed the effect of ambient pressure and heat release rate on fire suppression performance.
  • Measured extinguishing times and temperature reductions for various fire source sizes.
  • Under low pressure, extinguishing times decreased with increased heat release rate.
  • Extinguishing times varied by fire pan size, showing reductions between 2.8 s and 8.45 s under low pressure.
  • Hydrogen fluoride concentration was 59.2% higher under normal pressure, indicating reduced toxicity under low pressure.

Abstract

To investigate the fire suppression effectiveness of perfluorohexanone in low-pressure environments, a self-built fire suppression experimental platform was utilized to analyze the influence of ambient pressure and heat release rate on its performance. The results demonstrate that under normal-pressure conditions, the extinguishing time increases with the heat release rate of the fire source, whereas under low-pressure conditions, the extinguishing time decreases as the heat release rate increases. Specifically, under normal pressure, the extinguishing times for Fire Pan A (10 cm × 10 cm × 10 cm), Fire Pan B (15 cm × 15 cm × 10 cm), and Fire Pan C (20 cm × 20 cm × 10 cm) were 5.03 s, 8.15 s, and 9.63 s, respectively. In contrast, under low pressure, the extinguishing times were significantly shorter, with reductions of 2.8 s, 6.59 s, and 8.45 s, respectively. In terms of temperature reduction, the flame temperature decreased by approximately 300 °C under normal pressure, while under low pressure, it decreased by only about 100 °C. The concentration of hydrogen fluoride (HF) produced after extinguishment was relatively low, indicating limited toxicity. The HF concentration under normal pressure was, on average, approximately 59.2% higher than that under low-pressure conditions. Based on parameters such as the mass of the extinguishing agent, temperature changes, and hydrogen fluoride content, a fire suppression effectiveness model was established. The results show that the weight coefficient for chemical inhibition intensity is as high as 38.81, significantly exceeding other factors, demonstrating that perfluorohexanone primarily relies on chemical inhibition to interrupt the combustion chain reaction. This conclusion provides an important theoretical basis for the design and optimization of fire suppression systems in low-pressure environments such as aviation and high-altitude areas.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Liu et al. (2025) studied this question.

synapsesocial.com/papers/693624ce4fa91c937236cdd2https://doi.org/10.3390/fire8120472
Ask AI
Helpful
Bookmark
Share
View Full Paper