PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
January 14, 2026Pharmaceutics0 citationsOpen Access

Two Comprehensive Liquid Chromatography High-Resolution Mass Spectrometry (UPLC-MS/MS) Multi-Methods for Real-Time Therapeutic Drug Monitoring (TDM) of Five Novel Beta-Lactams and of Fosfomycin Administered by Continuous Infusion

View Full Paper
ITIlaria TrozziBGBeatrice GiorgiRPRiccardo De Paola

Key Points

  • This research aims to develop and validate methods for therapeutic drug monitoring of beta-lactams and fosfomycin in plasma.
  • Developed two UPLC–qTOF–MS/MS methods for simultaneous quantification.
  • Plasma samples prepared by protein precipitation with methanol and internal standards.
  • Validated methods by assessing selectivity, linearity, precision, accuracy, and stability.
  • Methods demonstrated excellent linearity (R2 ≥ 0.998) across a calibration range of 1.56–500 µg/mL.
  • Extraction recovery exceeded 92%, and stability was confirmed up to five days at 4 °C.
  • No carry-over or isobaric interferences were detected.

Abstract

Background/Objectives: Therapeutic drug monitoring (TDM) of β-lactams (BL), BL/β-lactamase inhibitor (BLI) combinations (BL/BLIc), and of fosfomycin may play a key role in optimizing antimicrobial therapy and in preventing resistance development, especially when used by continuous infusion in critically ill or immunocompromised patients. Unfortunately, analytical methods for simultaneously quantifying multiple BL/BLIc in plasma are still lacking. Methods: The aim of this study was to develop and validate two rapid, sensitive, and accurate UPLC–qTOF–MS/MS methods for the simultaneous quantification of five novel β-lactam or β-lactam/β-lactamase inhibitor combinations (ceftolozane/tazobactam, ceftazidime/avibactam, meropenem/vaborbactam, cefiderocol, and ceftobiprole) along with fosfomycin. Methods: Human plasma samples were prepared by protein precipitation using methanol containing isotopically labeled internal standards. Chromatographic separation was achieved within 10–12 min using two Agilent Poroshell columns (EC-C18 and PFP) under positive and negative electrospray ionization modes. The method was validated according to the EMA guidelines by assessing selectivity, linearity, precision, accuracy, matrix effects, extraction recovery, and stability. Results: The methods exhibited excellent linearity (R2 ≥ 0.998) across the calibration ranges for all of the analytes (1.56–500 µg/mL), with limits of quantification ranging from 1.56 to 15.62 µg/mL. Intra- and inter-day precision and accuracy were always within ±15%. Extraction recovery always exceeded 92%, and the matrix effects were effectively corrected through isotopic internal standards. No carry-over or isobaric interferences were observed. All the analytes were stable for up to five days at 4 °C, but the BL and BL/BLIc stability was affected by multiple freeze–thaw cycles. Conclusions: These UPLC-qTOF-MS/MS multi-analyte methods enabled a simultaneous, reliable quantification in plasma of five novel beta-lactams and of fosfomycin. Robustness, high throughput, and sensitivity make these multi-methods feasible for real-time TDM, supporting personalized antimicrobial dosing and improved therapeutic outcomes in patients with severe or multidrug-resistant infections.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Trozzi et al. (2026) studied this question.

synapsesocial.com/papers/6966e73f13bf7a6f02bffdb8https://doi.org/10.3390/pharmaceutics18010091
Ask AI
Helpful
Bookmark
Share
View Full Paper