PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
January 17, 2026Philosophical Transactions of the Royal Society A Mathematical Physical and Engineering Sciences0 citations

The triad of trust: solutions to practical inconsistencies in T , T 90 and in situ traceability

View Full Paper
PRPatrick Michael Carl RourkeATAndrew Douglas William ToddSDSergey Dedyulin

Key Points

  • This research aims to identify and address the practical inconsistencies arising from the 2019 redefinition of the kelvin in temperature measurement.
  • Analysis of the implications of the Mise en pratique for thermometer users
  • Discussion of the challenges posed by coexisting T and T90 thermometers
  • Exploration of solutions focusing on traceability, equivalence, and competence in metrology.
  • Identified inconsistencies in traceability with new thermometer technologies
  • Proposed solutions enhance user trust in temperature measurements
  • Emphasized the importance of maintaining measurement integrity alongside technological advancements.

Abstract

Abstract The 2019 redefinition of the kelvin and its accompanying Mise en pratique (MeP-K) herald a bold new future for the thermometry community. The MeP-K offers a blueprint for putting the kelvin into practice, and the proliferation of the new realization options it enables will lead to both benefits and practical inconsistencies for thermometer users. Users have been accustomed to a straightforward International Temperature Scale of 1990 T90 measurement chain with traceability and trust assured by national metrology institutes (NMIs). In contrast, the emerging world of coexisting T and T90 thermometers, with some offering in situ temperature traceability unconnected to NMIs, will challenge this straightforward measurement chain. Here, we discuss practical solutions to the practical inconsistencies users will encounter. These solutions focus on the triad of trust in metrology—traceability, equivalence and competence—to allow thermometry end users to broadly benefit from new technologies while maintaining trust in measurements and minimizing net disruption. This article is part of the Theo Murphy meeting issue ‘The redefined kelvin: progress and prospects’.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Rourke et al. (2026) studied this question.

synapsesocial.com/papers/696b25cfd2a12237a9349182https://doi.org/10.1098/rsta.2024.0461
Ask AI
Helpful
Bookmark
Share
View Full Paper