PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
January 18, 2026Archives of Gynecology and Obstetrics1 citationsOpen Access

Ergonomic evaluation of the Senhance® robotic system in minimally invasive gynecologic procedures versus conventional laparoscopy: an exploratory study focusing on surgeon’s muscle activity

View Full Paper
BKBernhard KrämerJAJürgen AndressLWLeonhard Wohlmeiner

Key Points

  • To assess if the Senhance® Surgical System reduces muscular demands in laparoscopic surgery and to evaluate its eye-tracking feature's impact on strain.
  • Within-subject design comparing robotic-assisted and conventional laparoscopic procedures
  • Two experienced surgeons performed 11 robotic and 12 conventional procedures
  • Muscular demands were measured using surface electromyography on seven muscles
  • Posture was assessed with position sensors and discomfort was rated by surgeons
  • An eyestrain questionnaire was administered after each procedure.
  • Four out of seven muscles showed reduced activity with Senhance®
  • Significant increase in muscle activation was noted only in the left shoulder-neck area during robotic surgery
  • Surgeons reported no musculoskeletal discomfort in either method
  • Mental and physical workload felt similar across both surgeries
  • Working precision was rated higher in standard laparoscopy.

Abstract

Abstract Purpose Primary: To evaluate whether robotic-assisted laparoscopic surgery using the Senhance® Surgical System has the potential to reduce muscular demands compared to conventional laparoscopy. Secondary: To verify that the novel eye-tracking feature for zoom and the selection of functions in the Senhance® System menu is not associated with increased eyestrain or neck strain. Methods In a within-subject design, 2 experienced surgeons performed 11 robot-assisted and 12 conventional laparoscopic procedures. Muscular demands were monitored throughout surgical procedures by assessing the muscle activity via bipolar surface electromyography of seven muscles of the lower back, shoulder–neck, and forearms. Surgeons’ head, arm, and torso posture was assessed by gravimetrical position sensors. Furthermore, musculoskeletal discomfort, mental and physical workload, task difficulty and working precision were rated by the surgeons. In addition, a ten-item eyestrain questionnaire was administered after each surgical procedure. Results Four out of seven muscles were relieved when working with Senhance®. Only in the left shoulder–neck area there was a statistically significant increase in muscle activation associated with robotic-assisted surgery. Changes in surgeons’ posture related to the surgical technique corresponded to the changes in muscle activation. Furthermore, surgeons reported no musculoskeletal discomfort under both conditions and similar levels of workload (mental and physical), and task difficulty. Working precision was subjectively rated to be better during standard laparoscopy. No eyestrain occurred during any of the procedures. Conclusion This exploratory study identified the potential of the Senhance® Surgical System for ergonomic improvements and indicated no impairments by the novel eye-tracking feature on muscle demands and eyestrain. Follow-up studies with larger and more diverse indications are needed that also consider clinical outcomes, which were not part of the present study.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Krämer et al. (2026) studied this question.

synapsesocial.com/papers/696c772aeb60fb80d13957cfhttps://doi.org/10.1007/s00404-025-08292-0
Ask AI
Helpful
Bookmark
Share
View Full Paper