PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
January 18, 2026Polymers0 citationsOpen Access

Dual-Functional Polyurethane Sponge-Based Pressure Sensors Incorporating BZT/BTO, Polypyrrole, and Carbon Nanotubes with Energy Generation Capability

View Full Paper
NONurhan OnarBKBaljinder K. Kandola

Key Points

  • The aim is to develop a flexible and wearable pressure sensor with high sensitivity and energy generation capability.
  • Engineered a multilayer conductive architecture on a sponge substrate.
  • Coated the sponge with barium zirconium titanate, polypyrrole, and carbon nanotubes.
  • Measured sensitivity, response time, recovery period, and voltage output under pressure.
  • Achieved a sensitivity of 9.71 kPa–1 between 0 and 9 kPa.
  • Demonstrated a rapid response time of 40 ms and recovery period of 60 ms.
  • Produced a voltage output of 1.25 V through piezoelectric mechanisms.

Abstract

Flexible and wearable pressure sensors are essential for monitoring of human motion and are distinguished by their increased sensitivity and outstanding mechanical robustness. In this study, we systematically engineered a flexible and wearable pressure sensor with a multilayer conductive architecture, arranging a sponge substrate coated in a consecutive manner with a barium zirconium titanate thin film, followed by polypyrrole, multiwalled carbon nanotubes, and eventually polydimethylsiloxane. The foundation of additional conductive pathways is enabled via the utilization of a porous framework and the hierarchical arrangement, causing the achievement of an excellent sensitivity of 9.71 kPa–1 (0–9 kPa), a rapid 40 ms response time, and a fast 60 ms recovery period, combined with a particularly low detection limit (125 Pa) and an extended pressure range from 0 to 225 kPa. Furthermore, the integration of a rough and porous barium zirconium titanate/barium titanate thin film is expected to deliver a voltage output (1.25 V) through piezoelectric working mechanisms. This study possesses the potential to provide an innovative architecture design for advancing the development of future electronic devices for health and sports monitoring.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Onar et al. (2026) studied this question.

synapsesocial.com/papers/696c77afeb60fb80d1395f38https://doi.org/10.3390/polym18020241
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Polyvinylpyrrolidone modified barium zirconate titanate /polyvinylidene fluoride nanocomposites as self-powered sensor2018 · 61 citations
  2. 2Fabrication of polypyrrole coated superhydrophobic surfaces for effective oil/water separation2022 · 35 citations
  3. 3Conductive elastic sponge-based triboelectric nanogenerator (TENG) for effective random mechanical energy harvesting and ammonia sensing2020 · 118 citations
  4. 4EFFECT OF FIBRE TYPE AND STRUCTURE IN DESIGNING ORTHOPAEDIC WADDING FOR THE TREATMENT OF VENOUS LEG ULCERS2006 · 6 citations
  5. 5Design and development of novel bandages for compression therapy2003 · 13 citations