January 18, 2026Earthquake Engineering & Structural Dynamics0 citations

Experimental Study on Seismic Performance of Hybrid Coupled Wall Systems With Friction Steel Truss Coupling Beams

View Full Paper
QTQi TangYCYao CuiHWHaoyang Wang

Key Points

  • This study aims to evaluate the seismic performance of a new hybrid coupled wall system integrating friction steel truss coupling beams.
  • Conducted a large-scale quasi-static test on a three-story subassemblage from a 24-story prototype.
  • Applied varying axial loads to simulate realistic boundary conditions.
  • Measured performance under different earthquake levels including service level, design basis, maximum considered, and very rare earthquakes.
  • Wall piers remained elastic under very rare earthquakes, with inelastic deformation in the friction dampers.
  • Friction steel truss coupling beams contributed 67% of the total energy dissipation.
  • The FHCW system showed excellent ductility and a maximum roof drift of 0.02 rad, indicating effective seismic resilience.

Abstract

ABSTRACT The reinforced concrete coupled wall system is a prevalent lateral force‐resisting system for mid‐ to high‐rise buildings. To enhance the seismic performance of such systems, this study proposes a friction hybrid coupled wall (FHCW) system, which integrates friction steel truss coupling beams (FTCBs). The FHCW system is designed with explicit performance objectives across different earthquake levels: it remains elastic under service level earthquakes (SLEs); experiences first and second sliding of the FTCBs during design basis (DBE) and maximum considered earthquakes (MCE), respectively; and allows wall pier reinforcement to yield under very rare earthquakes (VREs). To validate the seismic performance of the proposed system, a large‐scale quasi‐static test was performed on a three‐story subassemblage extracted from a 24‐story prototype. Realistic boundary conditions were simulated by applying varying axial loads to the wall piers. Test results confirmed the predefined performance objectives. Up to the VRE level, wall piers remained elastic, with inelastic deformation concentrated in the replaceable friction dampers of FTCBs. The FTCBs exhibited full and stable hysteretic responses, contributing 67% of the total energy dissipation. Beyond VRE, plastic hinges formed at the wall bases, eventually leading to flexural failure. The FHCW specimen achieved a maximum roof drift of 0.02 rad, while FTCBs attained a chord rotation up to 0.045 rad, demonstrating excellent ductility and considerable safety redundancy. An elastic coupling ratio of 67% was measured, indicating reliable FTCB‐to‐wall‐pier connections and efficient coupling action. The results confirm that the FHCW system offers a promising alternative for the design of resilient building structures.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Tang et al. (2026) studied this question.

synapsesocial.com/papers/696c785beb60fb80d1396845https://doi.org/10.1002/eqe.70131