PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
January 22, 2026Medicina0 citationsOpen Access

Combined Clavicular Hook Plate and Coracoid Screw Fixation for Coracoid Process Fractures Associated with Acromioclavicular Joint Dislocation

View Full Paper
BLBong Gun LeeYLYoung Seok LeeCLChang‐Hun Lee

Key Points

  • The aim is to evaluate the clinical and radiological outcomes of simultaneous fixation for coracoid process fractures with acromioclavicular joint dislocation.
  • Conducted a retrospective review of 15 patients with Ogawa type I fractures and joint dislocation.
  • Patients underwent fixation using a clavicular hook plate and a coracoid screw.
  • Assessed clinical outcomes including shoulder range of motion and pain using VAS and Constant score.
  • Evaluated radiologic outcomes via computed tomography for fracture union and joint alignment.
  • Mean shoulder range of motion was 168° for forward elevation and 161° for abduction.
  • VAS score averaged 0.4, indicating low pain levels.
  • All patients achieved CT-confirmed union of the fracture.
  • No residual AC joint subluxation was observed during follow-up.
  • All patients successfully returned to sports and daily activities.

Abstract

Background and Objectives: Coracoid process (CP) fractures combined with acromioclavicular (AC) joint dislocation are extremely rare, and evidence guiding optimal surgical management remains limited. This retrospective, single-center case series study evaluated clinical and radiologic outcomes after simultaneous fixation of both lesions using a clavicular hook plate and a coracoid screw. Materials and Methods: We retrospectively reviewed 15 consecutive patients with Ogawa type I CP fractures combined with AC joint dislocation who underwent clavicular hook plate and coracoid screw fixation between March 2019 and May 2024. Clinical outcomes at final follow-up included shoulder range of motion (ROM), visual analog scale (VAS) for pain, and the Constant score. Radiologic outcomes included CP union confirmed by computed tomography (CT) and residual AC joint subluxation. Results: The cohort comprised 13 men and 2 women with a mean age of 55.2 years, and the mean final follow-up was 40.2 months. At final follow-up, mean ROM was 168° for forward elevation, 161° for abduction, and 69° for external rotation at the side, with internal rotation to L1. The mean VAS score was 0.4 and the mean Constant score was 97. CT-confirmed union of the CP fracture was achieved in all patients, and no residual AC joint subluxation was observed. All patients returned to sports and activities of daily living. Conclusions: In this series, simultaneous fixation using a clavicular hook plate and a coracoid screw provided reliable stabilization for CP fractures with AC joint dislocation, achieving consistent CP union, restoration of AC joint alignment, and favorable clinical outcomes. However, given the retrospective, non-comparative study design, these findings should be interpreted with caution, and further comparative studies are warranted.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Lee et al. (2026) studied this question.

synapsesocial.com/papers/6971bd6a642b1836717e21eahttps://doi.org/10.3390/medicina62010212
Ask AI
Helpful
Bookmark
Share
View Full Paper