January 22, 2026JACOW0 citationsOpen Access

Transverse and longitudinal beam diagnostics and characterizations at IUAC-high current injector

View Full Paper
RHR.V. HariwalSKSarvesh KumarPLP. S. Lakshmi

Key Points

  • This research aims to enhance beam quality through diagnostic techniques in a high current injector.
  • Utilized both destructive and non-destructive beam diagnostics for accurate measurements.
  • Conducted tests on 20Ne9+ ion beams to analyze energy spread.
  • Implemented slits at the image plane for beam energy reduction.
  • Observed an energy spread of approximately 1% causing debunching in the beam.
  • Adjusted slits effectively reduced the energy spread by over fifty percent.

Abstract

The High Current Injector features normal-conducting RF Linac structures intended to accelerate various ion species with a mass-to-charge ratio of up to 6, achieving a maximum output energy of 1.8 MeV/u. It can deliver an intense analyzed beam up to 100pnA at the target. To preserve the beam quality at the target and to improve the performance of RF cavities and beam transmission, both destructive and non-destructive, fast and precise transverse and longitudinal beam diagnostics (including FFCs and CPOs for phase space and ToF measurements) are deployed in LEBT, MEBT and HEBT section of HCI. The beam energy was validated through the existing Surface Barrier Detector measurement setup. Recently, during 20Ne9+ beam test, we observed a notable energy spread of approximately 1%, which led to pronounced debunching and a complete loss of the necessary signal component in the downstream BPMs. To mitigate the energy spread, slits have been installed at the image plane of the fourth achromatic bending magnets, and it was observed that optimally adjusting the slits can reduce the spread by over fifty percent. This paper will present the latest measurements, challenges and future plans.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Hariwal et al. (2026) studied this question.

synapsesocial.com/papers/6971bdcf642b1836717e2837https://doi.org/10.18429/jacow-ibic2025-wepmo27
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Low-energy ion beam diagnostics: an integrated solution2024 · 1 citations
  2. 2Achievement of high-current continuous-wave deuteron injector for linear IFMIF prototype accelerator (LIPAc)2024 · 5 citations
  3. 3KONUS dynamics for a 750 MHz IH-based injector2026 · 2 citations
  4. 4Development of a non-intercepting weak beam current measurement electronics for Heavy Ion Accelerator Facility in Lanzhou2024 · 1 citations
  5. 5Beam dynamics study of the high-power electron beam irradiator using niobium-tin superconducting cavity2024