Beam measurement during swap-out injection of the APS-U storage ring

View Full Paper
WCWeixing ChengABAdam BrillRHRan Hong

Key Points

  • The aim is to characterize beam dynamics during swap-out injections in the APS-U storage ring.
  • Utilized 20 Beam Position Monitors equipped with high-precision single-bunch electronics.
  • Measured turn-by-turn positions of the injecting bunch.
  • Assessed longitudinal phase and energy of the injecting bunch.
  • Implemented bunch-by-bunch feedback systems to measure transient beam motions.
  • Successfully measured beam positions during swap-out injections.
  • Accurate assessments of longitudinal phase and energy were achieved.
  • Transient beam motions were effectively measured and analyzed.

Abstract

The Advanced Photon Source Upgrade (APS-U) implements a novel swap-out injection scheme. To comprehensively characterize the beam dynamics during swap-out injections, approximately 20 Beam Position Monitors (BPMs) in the initial sections of the storage ring have been equipped with high-precision single-bunch electronics. These systems are capable of measuring the turn-by-turn positions of the injecting bunch. Using similar techniques, the longitudinal phase and energy of the injecting bunch can be accurately assessed. Additionally, bunch-by-bunch feedback systems have been used to measure transient beam motions, extending their primary functionality of suppressing coupled bunch instabilities. This paper presents the results of beam measurements during swap-out injections utilizing these advanced systems.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Cheng et al. (2026) studied this question.

synapsesocial.com/papers/6971be8d642b1836717e3348https://doi.org/10.18429/jacow-ibic2025-wepmo18
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Design and performance of a novel data acquisition and processing system for the APS Upgrade front end XBPM2025
  2. 2The Role of Beam Diagnostics during APS-U Commissioning2026
  3. 3Longitudinal profile measurements of particle beams with deconvolution in the APS-U Storage-ring2026
  4. 4APS upgrade: Commissioning the world’s first light source based on swap-out injection2026
  5. 5The control and monitoring system for the APS-U front-end XBPM2026