PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
January 23, 2026Angewandte Chemie International Edition5 citations

Eco‐Friendly Preparation of High‐Quality Lead‐Free Halide Ferroelectric Solid‐Solution Toward High‐Performance X‐ray Detection

View Full Paper
YZYi ZhangHokkaido UniversityHLHongxia LiNorth Sichuan Medical UniversityCNCai NingJiangsu University of Science and Technology

Key Points

  • The aim is to develop a new lead-free halide ferroelectric material with enhanced X-ray detection capabilities and optimal environmental properties.
  • Used isothermal evaporation from a biomass-derived solvent, γ-valerolactone, for material preparation.
  • Developed lead-free halide ferroelectric solid-solution (HDA)Sb 1-x Bi x I 5 with varying x values.
  • Synthesized centimeter-sized single-crystals to improve material qualities.
  • Achieved a narrowest bandgap of 1.64 eV among Bi/Sb-based halide ferroelectrics.
  • Increased charge-carrier mobility-lifetime (µτ) product by approximately two orders of magnitude compared to (HDA)SbI 5.
  • Demonstrated an X-ray detector sensitivity of 1,040 µC Gy air −1 cm −2, with a remarkable peak sensitivity of 17,560 µC Gy air −1 cm −2, the highest reported among halide ferroelectrics.

Abstract

Abstract Bi/Sb‐based halide ferroelectrics have become promising lead‐free alternatives due to their excellent stability and environmental friendliness. However, their wide bandgaps and limited charge‐carrier mobility‐lifetime ( µτ ) product impede their optoelectronic performance. Here, we report a new eco‐friendly method for growing lead‐free halide ferroelectric solid‐solution (HDA)Sb 1‐x Bi x I 5 (x = 0–1) (HDA = hexane‐1,6‐diammonium), by isothermal evaporation from a biomass‐derived solvent, γ ‐valerolactone (GVL). The solid‐solution strategy, good material stability,‐ and high‐quality centimeter‐sized single‐crystals not only endow the (HDA)Sb 0.39 Bi 0.61 I 5 with the narrowest bandgap of 1.64 eV among Bi/Sb‐based halide ferroelectrics, but also enhance its µτ product by approximately two orders of magnitude compared with the parent (HDA)SbI 5 . Benefiting from these attributes and the intrinsic ferroelectric spontaneous polarization, the X‐ray detector based on (HDA)Sb 0.39 Bi 0.61 I 5 exhibits excellent self‐powered detection performance with a high sensitivity of 1,040 µC Gy air −1 cm −2 and a low detection limit of 0.25 nGy air s −1 . More excitingly, its detection sensitivity can reach 17,560 µC Gy air −1 cm −2 , which is the highest among reported halide ferroelectrics, and superior to that of most halide detectors. This work opens new avenues for the rational engineering of Bi/Sb‐based halide ferroelectrics for advanced optoelectronic applications.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Zhang et al. (2026) studied this question.

synapsesocial.com/papers/69730f34c8125b09b0d1f087https://doi.org/10.1002/anie.202525694
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Ultrafast high-endurance memory based on sliding ferroelectrics2024 · 182 citations
  2. 2Exploring Aqueous Solution‐Processed Pseudohalide Rare‐Earth Double Perovskite Ferroelectrics toward X‐Ray Detection with High Sensitivity2024 · 25 citations
  3. 3Multi‐Axial Self‐Driven X‐Ray Detection by a Two‐Dimensional Biaxial Hybrid Organic‐Inorganic Perovskite Ferroelectric2024 · 30 citations
  4. 4High-quality bulk hybrid perovskite single crystals within minutes by inverse temperature crystallization2015 · 1,912 citations
  5. 5Heavy pnictogens-based perovskite-inspired materials: Sustainable light-harvesters for indoor photovoltaics2023 · 14 citations