PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
January 23, 2026Energy and automation0 citationsOpen Access

The influence of stator winding resistance imbalance of an induction motor: evaluation of phase current asymmetry

View Full Paper
SPS. ProkopenkoVKV. KryvonosovVKV. Kryvonosov

Key Points

  • To evaluate how stator winding resistance imbalance affects current asymmetry in induction motors.
  • Assessed active resistances in stator windings of repaired induction motors.
  • Analyzed current imbalance under symmetrical and non-symmetrical supply voltages.
  • Employed the Mathcad system for calculating current asymmetry coefficients.
  • Identified that approximately 30% of repaired induction motors exhibit resistance asymmetry.
  • Established that resistance asymmetry varies current imbalance even with symmetrical voltage.
  • Demonstrated that changes in supply voltage and load current influence current asymmetry coefficients.

Abstract

Asymmetry of the active resistances of stator windings occurs in approximately 30% of repaired induction motors operating in power complexes of seaports, industrial enterprises, and ships. The resistance asymmetry causes current imbalance in the windings even under symmetrical supply voltage. In a non-symmetrical network, the asymmetry of active resistances can both increase and decrease the current asymmetry coefficient.The use of the Mathcad system enables the calculation of the current asymmetry coefficient depending on the deviation of the supply voltage, variation of stator winding resistances, load current, and supply frequency.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Prokopenko et al. (2025) studied this question.

synapsesocial.com/papers/69730f78c8125b09b0d1f347https://doi.org/10.31548/energiya5(81).2025.153