PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
January 24, 202624 citations

Pulsed field vs radiofrequency ablation for paroxysmal atrial fibrillation: the BEAT PAROX-AF trial.

View Full Paper
PJPierre JaisPNPetr NeuzilDSDaniel Scherr

Key Result

Single-shot pulsed field ablation did not show superior efficacy over point-by-point radiofrequency ablation in achieving freedom from atrial arrhythmias.

Key Points

  • This trial aims to compare the effectiveness of pulsed field ablation (PFA) to point-by-point radiofrequency ablation (RFA) in treating paroxysmal atrial fibrillation (AF).
  • Randomized trial design
  • Participants with paroxysmal atrial fibrillation
  • Comparison of single-shot pulsed field ablation and point-by-point radiofrequency ablation
  • Assessment of freedom from atrial arrhythmias and safety events.
  • No superior efficacy of PFA over RFA in achieving freedom from atrial arrhythmias
  • Fewer safety events were observed with PFA compared to RFA.

Structured PICO

Does single-shot pulsed field ablation improve single-procedure freedom from atrial arrhythmias compared to point-by-point radiofrequency ablation in patients with paroxysmal atrial fibrillation?

P
Population
Patients with paroxysmal atrial fibrillation
I
Intervention
Single-shot pulsed field ablation (PFA)
C
Comparator
Point-by-point radiofrequency ablation (RFA) using the CLOSE protocol
O
Outcome
Single-procedure freedom from atrial arrhythmiashard clinical

In patients with paroxysmal atrial fibrillation, single-shot pulsed field ablation was not superior to radiofrequency ablation for arrhythmia-free efficacy, though it was associated with fewer safety events.

Abstract

This randomized trial performed in patients with paroxysmal AF did not demonstrate superior efficacy of single-shot PFA vs point-by-point RFA using the CLOSE protocol regarding single-procedure freedom from atrial arrhythmias, despite fewer safety events being observed in this study with PFA.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Jais et al. (2026) studied this question. Single-shot pulsed field ablation did not show superior efficacy over point-by-point radiofrequency ablation in achieving freedom from atrial arrhythmias.