PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
January 25, 20265 citations

Transcatheter Tricuspid Valve Replacement in Patients With Cardiac Implantable Electronic Device Leads: The TRIPLACE Registry.

View Full Paper
BTBryan TraynorASAndrea ScottiRPRishi Puri

Key Result

Transcatheter tricuspid valve replacement in patients with CIED leads was performed safely, but significantly increased paravalvular leak and tricuspid regurgitation occurred with jailed leads.

Key Points

  • To evaluate the safety and effectiveness of transcatheter tricuspid valve replacement (TTVR) in patients with cardiac implantable electronic device (CIED) leads.
  • Conducted a global multicenter registry (TRIPLACE)
  • Inclusion of patients undergoing orthotopic TTVR
  • Monitoring of lead failure and tricuspid regurgitation outcomes
  • TTVR performed with low rates of lead failure
  • Higher incidence of paravalvular leak in patients with jailed leads
  • Close follow-up required for patients with pacing dependence

Structured PICO

Is orthotopic transcatheter tricuspid valve replacement (TTVR) safe and effective in patients with transvalvular CIED leads?

P
Population
Patients with transvalvular cardiac implantable electronic device (CIED) leads undergoing orthotopic transcatheter tricuspid valve replacement (TTVR)
I
Intervention
Orthotopic transcatheter tricuspid valve replacement (TTVR) with a jailed CIED lead
O
Outcome
Safety, effectiveness, lead failure rates, paravalvular leak, and residual tricuspid regurgitationsafety

Orthotopic TTVR is safe and feasible in patients with transvalvular CIED leads, though jailed leads increase the risk of paravalvular leak and residual tricuspid regurgitation, necessitating close follow-up and alternative pacing strategies.

Abstract

Orthotopic TTVR in patients with transvalvular CIED leads can be safely and effectively performed with low rates of lead failure. Significant paravalvular leak and residual tricuspid regurgitation is more common with a jailed lead. These patients require close CIED follow-up with alternative pacing strategies in place, particularly when pacing dependent. (Global Multicenter Registry on Transcatheter TRIcuspid Valve RePLACEment TRIPLACE; NCT06033274).

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Traynor et al. (2026) studied this question. Transcatheter tricuspid valve replacement in patients with CIED leads was performed safely, but significantly increased paravalvular leak and tricuspid regurgitation occurred with jailed leads.

synapsesocial.com/papers/6975b20efeba4585c2d6d8b5https://doi.org/10.1016/j.jacep.2025.12.027
Ask AI
Helpful
Bookmark
Share
View Full Paper