PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
February 2, 2026Aesthetic Surgery Journal Open Forum0 citationsOpen Access

Ultrasound-Assisted Pocket Creation in Subglandular Breast Augmentation

View Full Paper
HVHéctor Cesar Durán VegaAMAna Sofia MagallanesRCRaúl Manzaneda Cipriani

Key Points

  • The study aims to evaluate the safety, feasibility, and outcomes of ultrasound-assisted dissection in breast augmentation.
  • Conducted a prospective cohort study with healthy women aged 21-45.
  • Utilized real-time ultrasound-guided dissection after tumescent infiltration.
  • Measured outcomes included incision size, surgical time, postoperative pain, and complications.
  • Included 30 patients with an average age of 30 years.
  • Average incision size was 3.0 cm; surgical time averaged 40.2 minutes.
  • Postoperative pain remained minimal, with average VAS scores of 1.07 immediately and 1.7 at 24 hours after surgery.

Abstract

Abstract Background Electrocautery remains the conventional technique for breast pocket dissection in augmentation, but it produces thermal injury, postoperative pain, and delayed recovery. Ultrasound-assisted liposuction devices may provide a less traumatic approach for subglandular breast augmentation. Objectives To evaluate the safety, feasibility, and postoperative outcomes of real-time ultrasound-guided subglandular breast augmentation using ultrasonic dissection, hypothesizing that ultrasound-assisted dissection can be done with minimum tissue trauma, postoperative pain, and recovery time. Methods We conducted a prospective cohort including healthy women (aged 21–45 years) undergoing primary subglandular breast augmentation. All patients received real-time ultrasound-guided dissection using ultrasonic devices after tumescent infiltration. Outcomes included incision size, operative time, postoperative pain measured by Visual Analogue Scale (VAS), complications, and implant characteristics. Results We included 30 patients in the cohort. Mean age was 30 years (range 22-45, SD4.9). The average implant volume was 278.5 cc (205–375, SD 38.9), with a mean incision size of 3.0 cm (SD ±0.34). The mean surgical time was 40.2 minutes (24–55, SD 7.3). Pain intensity was minimal in the immediate postoperative period, with an average baseline VAS of 1.07 and a 24-hour VAS of 1.7 (SD ±0.78). No patient reported the need for extra or stronger analgesic medication, nor did they declare having taken it. Conclusions Image-guided ultrasonic subglandular dissection is technically feasible, safe, and well tolerated, with minimal pain, small incisions, and no major complications in short-term follow-up. This pilot study supports the concept of ultrasonic tissue separation in aesthetic breast surgery. Larger controlled studies with longer follow-up are needed to establish its role.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Vega et al. (2026) studied this question.

synapsesocial.com/papers/6980fb97c1c9540dea80d6b3https://doi.org/10.1093/asjof/ojag016
Ask AI
Helpful
Bookmark
Share
View Full Paper