PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
February 2, 2026JACOW0 citationsOpen Access

Bunch duration measurements in the APS-U booster

View Full Paper
JDJeffrey DoolingJCJoseph CalveyOMOsama Mohsen

Key Points

  • This research aims to measure the duration of particle bunches in the Advanced Photon Source Upgrade booster synchrotron.
  • Utilized the bunch duration monitor (BDM) for optical diagnostics.
  • Employed metal-semiconductor-metal detector with wide-band amplifier gain.
  • De-convolved output signal using the circuit’s impulse response.
  • Managed optical path de-focusing to counteract thermal steering.
  • Analyzed longitudinal oscillations against simulation data.
  • Bunch undergoes significant longitudinal oscillations after injection into the booster.
  • Non-linear effects due to detector saturation were noted.
  • Bunch energy increased from 425 MeV to 6 GeV during measurements.
  • Booster charge varied between 5 nC and 13 nC, affecting performance.

Abstract

We present the results of time-based, bunch length measurements in the Advanced Photon Source Upgrade booster synchrotron using the bunch duration monitor (BDM) optical diagnostic. The BDM diagnostic is based on the detection of visible-wavelength synchrotron radiation. The detector is a metal-semiconductor-metal device followed by 42 dB of wide-band amplifier gain. Bunch duration is determined by de-convolving the raw output signal with the circuit’s impulse response function. The BDM allows measurement of bunch duration over virtually the entire booster ramp. De-focusing in the optical path was necessary to overcome thermal steering from the in-tunnel mirror. Also, the effects of detector saturation must be considered to ensure a linear response. Presently, the booster increases bunch energy from 425 MeV to 6 GeV. Booster charge varies from 5 nC to 13 nC depending on storage ring operating modes. BDM data reveal that the bunch undergoes large longitudinal oscillations shortly after injection into the booster. The longitudinal oscillations are compared with elegant simulations. These oscillations are a source of injection loss especially at higher charge.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Dooling et al. (2026) studied this question.

synapsesocial.com/papers/6980fc55c1c9540dea80e203https://doi.org/10.18429/jacow-napac2025-mop019
Ask AI
Helpful
Bookmark
Share
View Full Paper