February 2, 2026Magnetic Resonance Materials in Physics Biology and Medicine0 citationsOpen Access

Influence of co-registration on lesion characterization in diffusion-weighted breast MRI

View Full Paper
LBLuise BrockALAndrzej LiebertHSHannes Schreiter

Key Points

  • To assess whether co-registering diffusion-weighted imaging enhances the differentiation of benign and malignant breast lesions in MRI.
  • Evaluated 16 co-registration methods on an in-house dataset with 138 cases.
  • Measured ADC values of segmented lesions based on A6702 thresholds.
  • Tested top methods on 40 unseen cases, 20 from in-house and 20 from external sources.
  • Used three readers for segmentation and evaluated agreement using statistical methods.
  • Rigid co-registration improved sensitivity from 93% to 97% and specificity from 10% to 30% for A6702 thresholds.
  • Mean ADC values showed no significant difference post co-registration (p > 0.05).

Abstract

Abstract Objective To evaluate if co-registering Diffusion-Weighted Imaging (DWI) before generating Apparent Diffusion Coefficient (ADC) maps can improve differentiating benign and malignant breast lesions in MRI based on the A6702 thresholds. Materials and methods This IRB-approved study involved an in-house dataset and the publicly available ACRIN-6698 dataset, both including multi b -value DWI. In phase one, 16 ANTs library-based co-registration methods were evaluated on a subset of n = 138 cases from our in-house cohort. The quantitative assessment included mean ADC values of manually segmented lesions (diagnostic metrics using individual and A6702-defined thresholds) and coefficient of Variation. In the second phase, the best-performing methods were tested for generalizability on an unseen set of 40 cases (20 from in-house and 20 from external dataset). Three blinded readers segmented lesions on co-registered and non-co-registered ADC maps. Agreement and consistency were evaluated via Bland–Altman, segmentation distance, and intraclass correlation coefficient. Results Rigid co-registration using DWI at b = 750 s/mm 2 as reference (b750-Rigid) improved accuracy of both optimal/conservative A6702 trial thresholds with sensitivity/specificity increasing from 93%/10% to 97%/30% and 100%/30% respectively. Mean ADC values were not significantly different after co-registration ( p > 0.05). Discussion Co-registration of DWI images before ADC map generation, particularly using b750-Rigid registration, seems promising for improving lesion classification in breast MRI. Further validation is warranted.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Brock et al. (2026) studied this question.

synapsesocial.com/papers/6980fe00c1c9540dea80fae8https://doi.org/10.1007/s10334-026-01324-z
Ask AI
Helpful
Bookmark
Share
View Full Paper