PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
February 2, 2026European Heart Journal - Cardiovascular Imaging0 citations

Comparison of different geometric assumptions of the mitral annulus and their impact on echocardiographic assessment

View Full Paper
DGD Garcia-MatoLGL Garcia-ElcanoEVE Giraldo Del Viejo

Key Result

An elliptical approach integrating A4C and A2C views reduced interobserver variability in mitral valve cross-sectional area estimation compared to the traditional A4C view (29.5% vs 38.0%).

Key Points

  • The research aims to evaluate how different geometric assumptions of the mitral valve annulus affect area estimations and interobserver variability.
  • Estimated mitral valve diameters from delineations at end-diastole for A4C and A2C views
  • Calculated cross-sectional area (CSA) using circular and elliptical assumptions
  • Analyzed correlation and consistency with Pearson’s correlation, linear regression and Bland-Altman
  • Quantified interobserver variability using coefficient of variation
  • A2C diameters were significantly larger than A4C by 0.27 cm (p = 0.03)
  • Weak correlation between CSA_2C and CSA_4C (R = 0.35)
  • CSA_4C showed the highest interobserver variability (38.0%), while CSA_4C2C showed reduced variability (29.5%)
  • Adopting the elliptical approach improves estimation consistency and correlates well with A4C measurements.

Study Design

Type

Observational (n=10)

Structured PICO

Does an elliptical assumption integrating A4C and A2C views improve measurement consistency and reduce interobserver variability compared to single-view circular assumptions for mitral valve annulus cross-sectional area estimation?

P
Population
10 patients (median age 72 years, 30% female) evaluated by 35 experienced sonographers to assess mitral valve annulus cross-sectional area.
E
Exposure
Cross-sectional area (CSA) estimation of the mitral valve annulus using an elliptical assumption integrating both apical 4-chamber (A4C) and apical 2-chamber (A2C) views (CSA_4C2C)
C
Comparator
CSA estimation based on a circular assumption using single views: A4C (CSA_4C) or A2C (CSA_2C)
O
Outcome
Agreement and consistency across CSA estimates and interobserver variabilitysurrogate

Using an elliptical approach that incorporates both apical 4-chamber and 2-chamber views for mitral valve annulus area quantification reduces interobserver variability and improves consistency compared to single-view circular assumptions.

Main Result

Absolute Event Rate: 29.5% vs 38%

Abstract

Abstract Introduction Accurate measurement of the mitral valve (MV) annulus is important for echocardiographic assessment of left ventricular stroke volume and, ultimately, essential for evaluating valvular disease. Current echocardiographic guidelines recommend estimating cross-sectional area (CSA) using the apical 4-chamber (A4C) view 1. However, these estimations rely on geometric assumptions that can introduce error 2, 3. Additionally, inherent interobserver variability in echocardiography poses further challenges to measurement reliability. Purpose This study aims to investigate the impact of MV geometric assumptions on CSA estimation and assess the robustness of these measurements in the context of interobserver variability, using annotations from a large cohort of experienced sonographers. Methods MV diameters were estimated from manual MV annulus delineations at end-diastole (ED) in A4C and apical 2-chamber (A2C) sequences on a cohort of 10 patients (median age: 72 y, IQR: 52-77; 70% male) by 35 experienced sonographers (mean expertise 5. 3 ± 2. 9 y). Ground truth delineations and ED frames were defined by a clinical committee of experts. CSA was calculated based on a circular assumption using A4C (CSA₄C) and A2C (CSA₂C) views, as well as an elliptical assumption integrating both of them (CSA₄C2C) (Figure 1). Agreement and consistency across CSA estimates were evaluated via Pearson’s correlation, linear regression and Bland-Altman analysis. Interobserver variability was quantified using the coefficient of variation. Results MV diameters in A2C were significantly larger than in A4C (mean difference 0. 27 ± 0. 69 cm; p = 0. 03), in contrast with prior literature 2, 4. The poor correlation between these measures (R = 0. 33) further underscores their inconsistency. Similarly, CSA₂C and CSA₄C were weakly correlated (R = 0. 35) and poorly agreed (mean difference: -1. 2 cm2; 95% LoA: -7. 4 to 5. 0 cm2), while CSA₄C2C provided intermediate values, as expected. These results revealed substantial discrepancies between geometric assumptions and confirmed the presence of a systematic bias when relying on single-view area estimations. Regarding interobserver variability in CSA estimations, CSA₄C showed the highest variability (38. 0 ± 9. 8%), while CSA₄C2C notably evidenced a reduced variability (29. 5 ± 6. 8%) (Figure 2). This reduction highlighted the added robustness of combining views, rather than relying on a single-plane measurement. Conclusion This study demonstrates that: (1) CSA estimates of the MV annulus are substantially influenced by geometric assumptions; and (2) the elliptical approach, incorporating both A4C and A2C views, enhances measurement consistency and substantially reduces interobserver variability while maintaining strong correlation with the traditional A4C assessment, preferred in clinical guidelines. Altogether supports the adoption of the elliptical approach for MV annular area quantification in echocardiography. Figure 1 Figure 2

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Garcia-Mato et al. (2026) conducted an observational in Mitral valve annulus assessment (n=10). Elliptical assumption integrating A4C and A2C views (CSA_4C2C) vs. Circular assumption using A4C view (CSA_4C) was evaluated on Interobserver variability in cross-sectional area estimations. An elliptical approach integrating A4C and A2C views reduced interobserver variability in mitral valve cross-sectional area estimation compared to the traditional A4C view (29.5% vs 38.0%).

synapsesocial.com/papers/6980fe8ac1c9540dea810a4ahttps://doi.org/10.1093/ehjci/jeaf367.126
Ask AI
Helpful
Bookmark
Share
View Full Paper