February 2, 2026Biomedical Chromatography0 citationsOpen Access

Development and Validation of a Novel and Cost‐Effective RP‐HPLC Method for the Separation of an Isomeric Impurity in Cariprazine Hydrochloride, an Antipsychotic Agent

View Full Paper
RSRajendra S. ShindeBGBrajadulal GhoshRSRakesh Sanvatsarkar

Key Points

  • This research aims to develop and validate an efficient RP-HPLC method for analyzing cis isomer impurities in cariprazine hydrochloride.
  • Developed using Intersil C8 stationary phase
  • Applied gradient elution with specific mobile phases
  • Maintained specific flow rate and temperature
  • Validated according to ICH guidelines
  • Assessed for robustness and accuracy
  • Achieved successful separation of cis isomer in cariprazine
  • Validated method showed precision and linearity
  • Method applicable across a range of concentrations up to 500%

Abstract

ABSTRACT Cariprazine is an active pharmaceutical ingredient; it is indicated for the treatment of schizophrenia and depressive episodes associated with bipolar disorder. It is also employed in the management of treatment of major depressive disorder. A specific, novel, and reverse‐phase high‐performance liquid chromatography (RP‐HPLC) method was developed for the analysis of cis isomer (isomeric impurity) in cariprazine hydrochloride, and this method is validated as per ICH guideline. By reviewing online sources, it was noted that no literature is available related to the separation of cis isomer from the cariprazine hydrochloride drug molecule. RP‐HPLC method was developed using stationary phase as Intersil C8, 250 mm, 4.6 mm, 5 μm. Gradient elution was employed using mobile phase A, which consisted of a 0.05 M monobasic ammonium phosphate (NH 4 H 2 PO 4 ) buffer adjusted to pH 6.0 ± 0.05 with triethylamine; mobile phase B consisted of a homogeneous combination of acetonitrile and water (80:20, v/v). The chromatographic separation was performed at a flow rate of 1.2 mL/min, with the column oven temperature maintained at 35°C and the detection wavelength set at 215 nm. The total run time of this method is 20 min. The selected diluent was a mixture of acetonitrile, water, and 88% orthophosphoric acid in a volumetric ratio of 60:40 and 0.1 v/v/v. The developed method is robust, precise, accurate and linear in a series of LOQ to 500% level from the specification concentration limit. The newly developed RP‐HPLC method is applicable for the analysis of cis isomer in cariprazine hydrochloride samples.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Shinde et al. (2026) studied this question.

synapsesocial.com/papers/6980fe9bc1c9540dea810d61https://doi.org/10.1002/bmc.70383
Ask AI
Helpful
Bookmark
Share
View Full Paper