February 6, 2026European Heart Journal0 citations

Time- and dose-dependent effect of high-sensitivity cardiac Troponin T compared to VARC-3 defined myocardial injury for predicting outcomes after Transcatheter Aortic Valve Implantation

View Full Paper
TSThorald StolteJRJ J ReichlPLPedro López‐Ayala

Key Result

Continuous hs-cTnT modeling revealed a time-varying increased risk for 1-year mortality post-TAVI, whereas the VARC-3 binary criterion was not prognostic (HR 1.65; 95% CI 0.98-2.76; p=0.06).

Key Points

  • To explore the non-linear and time-dependent effects of hs-cTnT on outcomes after TAVI compared to VARC-3 myocardial injury criteria.
  • Analyzed consecutive patients undergoing TAVI from 2011 to 2025.
  • Measured hs-cTnT concentrations pre- and post-procedurally.
  • Used multivariable Cox proportional hazards and spline survival models to analyze data.
  • Higher pre- and post-procedural hs-cTnT levels associated with increased risk of all-cause mortality at 1 year.
  • Prognostic significance of hs-cTnT as a binary variable was limited.
  • Dynamic risk assessment showed that higher levels of hs-cTnT prolonged mortality risk for 1 to 3 months.

Study Design

Type

Cohort (n=5,823)

Multicenter

Yes

Structured PICO

Does continuous, time-varying modeling of hs-cTnT predict 1-year mortality better than the dichotomous VARC-3 definition in patients undergoing TAVI?

P
Population
5,823 consecutive patients undergoing transcatheter aortic valve implantation (TAVI) at two tertiary university hospitals between 2011 and 2025 with available pre- and post-procedural hs-cTnT concentrations (out of 6,178 total patients).
I
Intervention
High-sensitivity cardiac troponin T (hs-cTnT) modeled as a continuous variable with time-varying and non-linear effects
C
Comparator
VARC-3 dichotomized definition of periprocedural myocardial injury (hs-cTnT > 35 or 70 times the upper reference limit of 14 ng/L)
O
Outcome
All-cause mortality at 1 yearhard clinical

Modeling hs-cTnT as a continuous variable with time-varying effects provides better prognostic information for mortality post-TAVI than the binary VARC-3 definition, revealing a prolonged period of increased risk proportional to biomarker levels.

Main Result

Effect estimate: HR 1.65 (95% CI 0.98-2.76)

p-value: p=0.06

Abstract

Abstract Background Pre- and post-procedural high-sensitivity cardiac troponin T (hs-cTnT) predict periprocedural myocardial injury (PPMI) and adverse events following transcatheter aortic valve implantation (TAVI). However, current studies have not incorporated time- and dose-dependent effects of hs-cTnT, limiting the precision of risk stratification and subsequent patient management. Purpose To investigate the non-linear and time-dependent effects of pre- and post-procedural hs-cTnT on outcomes after TAVI and compare these findings with the valve academic research consortium-3 (VARC-3) dichotomized definition of PPMI. Methods Consecutive patients undergoing TAVI at two tertiary university hospitals between 2011 and 2025 with available hs-cTnT concentrations measured pre- and post-procedurally were enrolled. Primary outcome was all-cause mortality at 1 year. A multivariable Cox proportional hazards model was fitted. To relax the proportional hazards assumption, allowing for hazard ratios (HRs) to vary over time, multivariable penalised spline survival models were fitted. In both models, hs-cTnT was modelled with splines allowing for non-linear effects. HRs were calculated for each timepoint 35 or 70 times the upper reference limit of 14 ng/L (VARC-3 criterion) was not prognostic for all-cause death (1.65, 95%CI: 0.98,2.76, p=0.06). Cox proportional hazard models handling hs-cTnT as a continuous variable showed that both higher pre- and post-procedural hs-cTnT levels were associated with increased hazard for all-cause mortality at 1 year (Figure 1A,B). Models allowing for time-varying HRs revealed that the hazard was highest early post-procedure and diminished over time (Figure 1 C-P), indicating a non-constant hazard. The duration of being at risk increased proportionally for higher pre- and post-procedural hs-cTnT and was longest for post-procedural hs-cTnT. For example, a patient with a post-procedural-hs-cTnT of 600 ng/mL remained at increased risk for mortality during the first 3 months, versus only 1 month with a post-procedural hs-cTnT of 50 ng/mL. Conclusions hs-cTnT as a binary variable, either through VARC-3 defined PPMI or direct use of hs-cTnT was not prognostic. The dynamic nature of risk post-TAVI could only be modelled when using hs-cTnT as a continuum. Higher levels of both pre- and post-procedural hs-cTnT are associated with a prolonged period of increased mortality risk, with duration ranging from 1 to 3 months when using a hs-cTnT of 14ng/L as reference. Incorporating time-varying and non-linear effects of hs-cTnT into risk prediction models could enhance clinical decision-making by tailoring post-procedural surveillance to individual patient risk profiles.Figure 1:Hazard, 3D- & mesh-plots

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Stolte et al. (2025) conducted a cohort in Transcatheter Aortic Valve Implantation (TAVI) (n=5,823). High-sensitivity cardiac troponin T (hs-cTnT) continuous modeling vs. VARC-3 dichotomized definition of PPMI was evaluated on All-cause mortality at 1 year (HR 1.65, 95% CI 0.98-2.76, p=0.06). Continuous hs-cTnT modeling revealed a time-varying increased risk for 1-year mortality post-TAVI, whereas the VARC-3 binary criterion was not prognostic (HR 1.65; 95% CI 0.98-2.76; p=0.06).

synapsesocial.com/papers/698585db8f7c464f2300988dhttps://doi.org/10.1093/eurheartj/ehaf784.3232