February 6, 2026Biosensors0 citationsOpen Access

Highly Sensitive Electrochemiluminescence Analysis of miRNA-107 Using AIE-Active Polymer Dots as Emitters

View Full Paper
ZXZhihong XuFujian University of Traditional Chinese MedicineXWXin WengFujian University of Traditional Chinese MedicineRLRuo-Mei LinFujian University of Traditional Chinese Medicine

Key Points

  • This research aims to develop a highly sensitive sensor for the detection of miRNA-107 for clinical use.
  • Developed an aggregation-induced electrochemiluminescence (AIECL) sensor for miRNA detection.
  • Characterized AIECL-active polymer dots using transmission electron microscopy and cyclic voltammetry.
  • Utilized black hole quencher-labeled hairpin DNA for signal modulation and dual conditions for hybridization and cleavage.
  • Achieved a wide linear response for miRNA-107 concentrations from 1.0 fM to 10.0 pM.
  • Noted a detection limit of 0.82 fM for miRNA-107.
  • Observed restoration of ECL signal upon target miRNA presence, enabling quantification.

Abstract

The ultrasensitive detection of microRNA-17 (miRNA-107) is required for clinical diagnosis. In this work, an aggregation-induced electrochemiluminescence (AIECL) sensor was developed for the quantification of miRNA-107, in which AIECL-active polymer dots (Pdots) were characterized by transmission electron microscopy, ultraviolet–visible spectroscopy, and cyclic voltammetry and used as ECL emitters. Black hole quencher-labeled hairpin DNA (HP-BHQ) was modified on the Pdot surfaces, resulting in the ECL signal of the Pdots being in the “off” state due to the resonant energy transfer (RET) between the BHQ and Pdots. In the presence of miRNA-107, HP-BHQ opened through RNA-DNA hybridization. Subsequently, the introduced duplex-specific nuclease (DSN) facilitated the cleavage of DNA in the RNA–DNA hybrid chain and led to the detachment of HP-BHQ from the electrode surface. The ECL signal of the Pdots recovered, i.e., to the “on” state. The variation in the ECL signal was related to the concentration of the target miRNA-107. As a result, the AIECL biosensor exhibited a wide linear response to miRNA-107 concentrations ranging from 1.0 fM to 10.0 pM, and a low detection limit of 0.82 fM. This work provides a novel platform for the sensitive analysis of miRNA.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Xu et al. (2026) studied this question.

synapsesocial.com/papers/698586388f7c464f2300a234https://doi.org/10.3390/bios16020099
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Enhanced Aggregation-Induced Delayed Electrochemiluminescence Triggered by Spatial Perturbation of Organic Dots2024 · 24 citations
  2. 2Exploring an ultra-sensitive electrochemiluminescence monitoring strategy for SARS-CoV-2 using hairpin-assisted cycling and dumbbell hybridization chain amplification2022 · 36 citations
  3. 3Serum levels of circulating microRNA-107 are elevated in patients with early-stage HCC2021 · 16 citations
  4. 4Flexible 3D nanofiber-based SERS biosensor for detection of miRNA-223-3p in early Laryngeal Cancer diagnosis2024 · 29 citations