PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
February 8, 2026European Heart Journal0 citations

Novel residual GAN for synthetic T2 mapping from OS-CMR to enhance myocardial edema detection

View Full Paper
FLFaezeh lotfikazemiMFM G F FriedrichMBM B Benovoy

Key Result

The novel R-GAN synthesized T2 maps from OS-CMR with up to 24.95 dB PSNR, 0.739 SSIM, and 0.923 PCC, achieving 99% correlation with original edema T2 curves.

Key Points

  • The study aims to develop and validate a novel R-GAN framework for synthesizing T2 parametric maps from OS-CMR, enhancing detection of myocardial edema.
  • Analyzed two datasets of matched OS-CMR and T2-weighted images from 2189 patients.
  • Preprocessed data through normalization, data augmentation, and image registration.
  • Developed and tested the R-GAN against the Pix2Pix model using PSNR, SSIM, and PCC metrics.
  • Evaluated both healthy and edematous myocardial regions using signal intensity measurements and T2 curve analyses.
  • R-GAN outperformed the Pix2Pix model across all evaluation metrics with PSNR values of 21.56 to 24.95 dB and SSIM scores of 0.672 to 0.739.
  • Synthesized values for edematous regions closely match original values, with strong signal intensity preservation.
  • EPG simulations showed a 99% correlation between synthesized T2 curves and original data.
  • High R² values (≥0.87) indicate fidelity of synthetic T2 curves, with nearly perfect correlation (0.99) between synthesized and ground truth data.

Structured PICO

Does a novel R-GAN framework improve the synthesis of T2 parametric maps from OS-CMR images compared to the Pix2Pix model for myocardial edema detection?

P
Population
2189 patients from two independent datasets with matched OS-CMR and T2-weighted images
I
Intervention
Novel Residual Generative Adversarial Network (R-GAN) framework for synthesizing T2 parametric maps from OS-CMR images
C
Comparator
Pix2Pix model
O
Outcome
Performance metrics including Peak Signal-to-Noise Ratio (PSNR), Structural Similarity Index Measure (SSIM), and Pearson Correlation Coefficient (PCC)surrogate

A novel R-GAN framework can accurately synthesize T2 parametric maps from OS-CMR images, offering a promising non-invasive approach for myocardial edema detection.

Abstract

Abstract Background Myocardial edema is a key factor of acute myocardial injury that substantially impairs microvascular function 1. Although T2-weighted MRI is essential for identifying this edema, its performance is often compromised by motion artifacts, prolonged acquisition times, and heterogeneous imaging protocols. 2, 3 In contrast, needle-free OS-CMR promising approach to provides functional insights and included T2 information 4-6. With recent advances in deep learning, especially in generative models 7, the synthesis of medical images has become a promising avenue. This study introduces a novel R-GAN coupled with an edema validation pipeline designed to synthesize T2 parametric maps from OS-CMR, thereby facilitating accurate edema detection. Purpose The purpose of this study is to develop and validate a novel R-GAN framework for synthesizing T2 parametric maps from OS-CMR images, enabling precise detection of myocardial edema. Methods Two independent datasets comprising matched OS-CMR and T2-weighted images from 2189 patients were analyzed. Preprocessing steps included normalization, data augmentation, and image registration. The proposed R-GAN (figure1), which incorporates residual blocks, was benchmarked against the Pix2Pix model using performance metrics such as PSNR, SSIM, and PCC. The evaluation focused on both edematous and healthy myocardial regions through signal intensity measurements, Extended Phase Graph (EPG) simulations, and T2 curve analyses performed with Python scripts and CVI42 software (Figure2). Results The R-GAN consistently outperformed the Pix2Pix model across all evaluated metrics. It achieved PSNR values ranging from 21.56 to 24.95 dB and SSIM scores between 0.672 and 0.739, and PCC scores between 0.862 to 0.923 compared to Pix2Pix’s 18.80–19.20 dB and 0.055–0.659 and 0.802 – 0.890, respectively. The edema signal intensity remained robust, with the original values of 452 for the edema ROI and 283 for the healthy ROI closely matching the synthesized values of 459.0 and 269.0, respectively. Extended Phase Graph (EPG) simulations revealed a 99% correlation between the synthesized T2 curves and the original data. Furthermore, analysis of two regions of interest, representing edematous and healthy myocardium, validated the fidelity of the synthetic T2 curves, as demonstrated by error metrics showing MAE values from 0.0007 to 0.0185, RMSE as low as 0.0008, and consistently high R² values (≥0.87). Notably, T2 curves for both edematous and healthy regions exhibited an almost perfect correlation (0.99) between the synthesized and ground truth data. Conclusion The novel R-GAN method demonstrates the feasibility of generating high-quality T2 maps from OS-CMR images, offering a promising non-invasive approach for myocardial edema detection. Further studies are warranted to validate these findings.Figure1 Figure2

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

lotfikazemi et al. (2025) studied this question. The novel R-GAN synthesized T2 maps from OS-CMR with up to 24.95 dB PSNR, 0.739 SSIM, and 0.923 PCC, achieving 99% correlation with original edema T2 curves.

synapsesocial.com/papers/698827f00fc35cd7a8846f78https://doi.org/10.1093/eurheartj/ehaf784.292
Ask AI
Helpful
Bookmark
Share
View Full Paper