February 8, 2026European Heart Journal0 citations

Efficiency, efficacy and safety of very high-power short-duration radiofrequency atrial fibrillation ablation

View Full Paper
IRI N E S RodriguesAGA GoncalvesALA Lobo

Key Result

Very high-power short-duration AF ablation achieved similar 12-month freedom from AF recurrence (86.6% vs 88.4%, p=0.51) with shorter procedure times and fewer ED visits (4.8% vs 14.9%, p=0.02).

Key Points

  • To compare clinical outcomes and procedural efficiency of very high-power short-duration atrial fibrillation ablation with standard techniques.
  • Included patients undergoing first atrial fibrillation catheter ablation between January 2021 and May 2024.
  • Compared very high-power short-duration RF applications (90W/4s) to standard power and duration (35W) RF applications.
  • Matched cohorts using propensity score analysis for comparison on various clinical outcomes and safety measures.
  • Monitored key metrics including freedom from AF recurrence, healthcare contacts, and total procedural times.
  • Freedom from AF recurrence was similar (86.6% vs 88.4%, p=0.510) between groups at 12 months.
  • Healthcare contacts were numerically higher in the SPD group but not statistically significant (10.5% vs 19.1%, p=0.08).
  • ED visits due to AF or CHF were more frequent in the SPD group (4.8% vs 14.9%, p=0.02).
  • Procedural times were significantly shorter in the vHPSD group (86.5min vs 100min, p<0.001).
  • Overall, both procedures demonstrated a favorable safety profile with low adverse effects.

Structured PICO

Does very high-power short-duration radiofrequency ablation reduce procedural time while maintaining clinical efficacy compared to standard power and duration ablation in patients undergoing first atrial fibrillation ablation?

P
Population
210 propensity-matched patients undergoing first atrial fibrillation catheter ablation (64.8% male, median age 62 years).
I
Intervention
Very high-power short-duration (vHPSD) radiofrequency ablation (90W/4s).
C
Comparator
Standard power and duration (SPD) radiofrequency ablation (35W guided by Ablation Index).
O
Outcome
Freedom from AF recurrence at 12 months.hard clinical

Very high-power short-duration RF ablation for atrial fibrillation significantly reduces procedural time while maintaining similar 12-month clinical efficacy and safety compared to standard ablation.

Abstract

Abstract Background Over the past few decades, atrial fibrillation (AF) catheter ablation has become an evidence-based, safe, and effective treatment. The procedure primarily focuses on pulmonary veins’ electrical isolation from the left atrium (LA), frequently using radiofrequency (RF) energy. Very high-power short-duration (vHPSD) RF applications can improve lesion quality and reduce procedural time compared to the standard approach, while ensuring similar clinical and safety outcomes. Purpose To compare vHPSD AF ablation with a matched control cohort undergoing standard power and duration (SPD) AF ablation at our centre, regarding clinical outcomes, procedural efficiency and safety. Methods We include all patients who underwent first AF catheter ablation between January 2021 and May 2024. SDP AF ablation (35W RF applications guided by Ablation Index) was performed until April 2022, after which vHPSD AF ablation (90W/4s) became the standard approach. The two groups were matched using a propensity score analysis and then compared regarding freedom from AF recurrence, contacts with healthcare (composite of emergency department (ED) visits due to AF or congestive heart failure (CHF); hospitalizations due to CHF, AF, acute coronary syndrome or stroke; electric cardioversion; or redo procedure), procedural efficiency, and safety. Results 308 patients were submitted to pulmonary vein (PV) isolation, and after the propensity score analysis, 210 patients were analysed (64,8% male, median age 62 years (IQR 54,7–67,5)). There were 105 patients in each group with comparable baseline characteristics. The median follow-up time was 364 days (IQR 207–548) for the vHPSD group and 729 days (IQR 559–730) for the STD group. Freedom from AF recurrence at 12 months was similar between groups in the survival analysis (86,6% vs 88,4%, p=0,510) (Figure 1). Healthcare contacts were numerically higher in the SPD group, but this difference was not statistically significant (10,5% vs 19,1%, p=0,08). However, ED visits due to AF or CHF were more frequent in the SPD group during follow-up (4,8% vs 14,9%, p=0,02). Total procedural time, ablation time, and RF application time were significantly shorter in the vHSPD arm (86,5min vs 100,0min, p0,001; 32,0min vs 45min, p0,001, and 7min vs 24,5min, p0,001, respectively). PV first-pass isolation (FPI) was obtained in 54,5% of patients in the vHPSD group and 72,0% in the SPD group (p=0,004). Overall, AF catheter ablation had a favourable safety profile, with a low prevalence of adverse effects, irrespective of the type of RF energy used (one pericardial effusion in the vHPSD group and one pericarditis in the SDP group). Conclusion VHPSD AF ablation was a more efficient technique with a shorter procedural time, achieving similar clinical outcomes despite having a lower FPI rate. Both procedures were safe with low prevalence of adverse effects.Freedom from AF recurrence.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Rodrigues et al. (2025) studied this question. Very high-power short-duration AF ablation achieved similar 12-month freedom from AF recurrence (86.6% vs 88.4%, p=0.51) with shorter procedure times and fewer ED visits (4.8% vs 14.9%, p=0.02).

synapsesocial.com/papers/6988291e0fc35cd7a88492c2https://doi.org/10.1093/eurheartj/ehaf784.481
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Clinical and procedural outcomes of very high-power short-duration vs. standard power ablation for pulmonary vein isolation2026
  2. 2High power short duration and very high power short duration protocol: a comparison between two effective strategies of atrial fibrillation transcatheter ablation with radiofrequency2024
  3. 3Safety profile and long-term efficacy of very high-power short-duration (60–70 W) catheter ablation for atrial fibrillation: results of a large comparative analysis2022 · 28 citations
  4. 4Network meta‐analysis and systematic review comparing efficacy and safety between very high power short duration, high power short duration, and conventional radiofrequency ablation of atrial fibrillation2023 · 12 citations
  5. 5Next-generation atrial fibrillation ablation: clinical performance of pulsed-field ablation and very high-power short-duration radiofrequency2024 · 14 citations