PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
February 11, 2026Digestive Diseases and Sciences0 citations

High-Resolution Impedance Manometry (HRIM) Using Yogurt (Viscosity Matched to Barium) for Bolus Clearance After Therapy in Achalasia

View Full Paper
AKAbhijeet KaradSSSridhar SundaramSGSuprabhat Giri

Key Points

  • To compare bolus clearance methods for achalasia patients treated with pneumatic dilatation.
  • Compared bolus clearance using TBE with barium and HRIM using yogurt in 20 patients.
  • Measured impedance bolus height and barium column height at 0, 1, and 5 minutes post-dilation.
  • Analyzed correlation between TBE and HRIM results with statistical methods.
  • IBH and TBE column height had similar measurements at 5 min, 4.6 cm vs. 4.25 cm.
  • Pearson correlation between TBE column and IBH was 0.73 at 5 minutes.
  • HRIM using yogurt showed good agreement with TBE for evaluating bolus clearance.

Abstract

Timed-barium esophagogram (TBE) is established test for assessing bolus clearance in achalasia post-treatment. However, radiation exposure is an important disadvantage. Esophageal bolus transit can be evaluated by HRIM. Previous studies comparing Impedance bolus height (IBH) using saline and TBE showed fair correlation. We compared bolus clearance by TBE versus HRIM using yogurt (viscosity matched to barium—calculated using Ostwald viscometer) in patients treated for achalasia. HRIM was performed using solid-state system (MMS, Netherlands). Twenty patients (age 45.1 years; 8 men) treated with pneumatic dilatation (Rigiflex, Boston Scientific) were evaluated with TBE (200 ml Barium) and HRIM (200 ml yoghurt) two weeks after dilation. Both tests were performed in upright position. Barium column height and impedance bolus height (IBH) were measured at 0, 1 and 5 min. Analysis of IBH was performed with spatial impedance variation plot overlayed on esophageal pressure topography. All patients gave consent, and protocol was approved by the IRB. At baseline, 5, 11 and 4 patients had type I, II and III achalasia, respectively. Eckardt score showed an improvement of 5 (range 1–9) points. The mean column height as measured by IBH and TBE at 5 min was similar (4.6 range 0–12.5 cm vs. 4.25 0–16 cm). Pearson correlation between the TBE column and IBH was 0.73 at 5 min. Bland Altman plot for bolus clearance as measured by TBE and HRIM showed good agreement between the modalities. There is good agreement between HRIM (performed using yoghurt) and TBE for evaluation of bolus clearance after therapy in achalasia patients. Single HRIM study done with viscosity matched liquid to barium can give information about bolus clearance and motor function in treated achalasia patients, avoiding radiation exposure.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Karad et al. (2026) studied this question.

synapsesocial.com/papers/698be001058ab1890a13ba97https://doi.org/10.1007/s10620-025-09663-y
Ask AI
Helpful
Bookmark
Share
View Full Paper