February 11, 2026Bioengineering0 citationsOpen Access

Development and Preliminary Assessment of a Tendon-Driven Thumb–Index Prosthesis with a Novel Hobbed-Pulley Actuation Mechanism

PGPatrícia GomesPSPedro J. S. C. P. SousaJNJ. Menezes Nunes

Key Points

  • To assess a new actuation mechanism for a tendon-driven prosthetic hand aimed at improving efficiency and user interaction.
  • Developed a hobbed tendon-pulley actuation mechanism.
  • Compared current-based and pressure-based control methodologies.
  • Tested grasping ability with various objects of different sizes, shapes, and weights.
  • The hobbed mechanism maintained cable tension effectively.
  • The current-based approach resulted in consistent grasping without tendon slippage.
  • Prosthesis successfully grasped various objects, enhancing user experience.

Abstract

Prosthetic hands have seen significant improvements in recent years, enabling increasingly more natural interactions between patients with upper limb loss and their environment. Nonetheless, progress is continuously being made to enhance user acceptance, which remains a major drawback in such systems. The efficiency of the actuation mechanism is a critical parameter when designing these devices. Maximising actuation approach efficiency enables the use of smaller and lighter motors, thus decreasing the overall weight of the solution. Simultaneously, increased efficiency contributes to more precise motor control. Within this context, the present work introduces a novel actuation concept. Conventional tendon–pulley mechanisms are often susceptible to tendon slippage; therefore, a hobbed tendon–pulley approach was investigated to maintain cable tension more consistently and efficiently. This approach aims to provide smoother operation, improved reliability, and a reduced risk of mechanical failure due to tendon slippage. Simultaneously, the capability of holding and maintaining a set force is of utmost importance in these systems, and the force-feedback system is usually a major concern. The present work also focuses on comparing current and pressure-based control methodologies for the developed prosthesis. The current-based approach had the significant advantage of not requiring external sensors to be assembled on the prosthesis and not relying on the point of application of force being inside the sensor’s active area. During these tests, the prosthesis successfully grasped various objects of different sizes, shapes, stiffnesses, and weights using a current-based approach, without observable tendon slippage.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Gomes et al. (2026) studied this question.

synapsesocial.com/papers/698c1cd3267fb587c655f98bhttps://doi.org/10.3390/bioengineering13020197
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1A Bioinspired Tendon-Driven Hand Prosthesis: Coupled FatigueWear Analysis and Shape Memory Alloy Integration for Durability Enhancement2026
  2. 2HandMECH: Biomechanically Inspired 3D-Thumb-Trajectory for a Body-Powered Hand Prosthesis2026
  3. 3Development of a Low-Cost 3D-Printed Upper Limb Prosthetic Device with Hybrid Actuation for Partial Hand Amputees2024 · 1 citations
  4. 4Hand Prosthesis with Soft Robotics Technology and Artificial Intelligence for Fine Motor Control2026
  5. 5A Lightweight and Versatile Prosthetic Hand for Daily Grasping2026