February 12, 2026Clinical Implant Dentistry and Related Research0 citations

Comparison of Five Osteotomy Protocols on Implant Stability and Postoperative Anxiety: A Randomized Controlled Trial

View Full Paper
RKRozerin KonukluSKSercan Küçükkurt

Key Points

  • This research aims to compare five different osteotomy protocols in terms of their influence on implant stability and postoperative anxiety.
  • Conducted a randomized controlled trial with 100 healthy adults, each receiving a macrodesign implant.
  • Participants were randomly assigned to one of five osteotomy techniques: high-speed, moderate-speed, ultra-low-speed drilling, osseodensification, and bone condensation.
  • Insertion torque was recorded at placement and ISQ was measured at various time points from placement to 3 months postoperation.
  • Postoperative anxiety was assessed using a VAS scale immediately after the procedure.
  • All groups achieved mean insertion torque values exceeding 30 Ncm and baseline ISQ values greater than 80.
  • Moderate-speed drilling showed the most consistent ISQ increase over time, especially at 3 months.
  • Postoperative VAS-anxiety levels decreased significantly across all groups; bone condensation technique showed the greatest reduction in anxiety.

Abstract

ABSTRACT Purpose This randomized controlled clinical trial compared five implant osteotomy techniques—high‐speed drilling (800 rpm), moderate‐speed drilling (300 rpm), ultra‐low‐speed drilling (50 rpm), osseodensification, and bone condensation—with respect to insertion torque (IT), early implant stability quotient (ISQ) progression, and immediate postoperative VAS‐anxiety during early osseointegration. Materials and Methods One hundred healthy adults each received a single identical macrodesign implant and were randomly allocated to five osteotomy protocols ( n = 20/group). Insertion torque was recorded at placement. ISQ was measured at placement (T0), 1 week (T1), 1 month (T2), 2 months (T3), and 3 months (T4). Immediate postoperative patient‐reported anxiety was assessed using a 10‐cm visual analog scale (VAS). Sites exhibiting IT 80. Moderate‐speed drilling (300 rpm) demonstrated the most consistent ISQ increase over time and achieved the highest stability at T4 (adjusted p < 0.05). High‐speed drilling (800 rpm) produced the highest initial IT, particularly in high‐density bone. Osseodensification showed transient mid‐healing ISQ gains, whereas bone condensation exhibited a progressive decline in ISQ values. Immediate postoperative VAS‐anxiety decreased significantly in all groups ( p < 0.001); osseodensification was associated with higher residual anxiety, while bone condensation demonstrated the greatest reduction (adjusted p < 0.05). Conclusions Osteotomy technique influenced both mechanical stability trajectories and immediate postoperative patient‐reported VAS‐anxiety. Moderate‐speed drilling at 300 rpm provided the most balanced stability profile within the 3‐month follow‐up. Osteotomy selection should be individualized according to bone density, mechanical requirements, and patient‐related factors. Trial Registration: ClinicalTrials.gov identifier: NCT07234214

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Konuklu et al. (2026) studied this question.

synapsesocial.com/papers/698d6dd15be6419ac0d52faehttps://doi.org/10.1111/cid.70125
Ask AI
Helpful
Bookmark
Share
View Full Paper