Preliminary Design and Parametric Study of Prestressed Stayed Beam–Columns with a Core of Spun Concrete

View Full Paper
SISaulius IndriūnasVilnius Gediminas Technical UniversityRKRomualdas KliukasAJAlgirdas Juozapaitis

Key Points

  • This research aims to evaluate the characteristics and performance of an innovative prestressed stayed beam-column system using spun reinforced concrete.
  • Analyzed an innovative prestressed stayed beam-column structure with a spun concrete core.
  • Calculated internal forces and displacements of the structure.
  • Evaluated stress-strain states and bending moments of the spun concrete core.
  • Discussed rational parameters for cross-sections and prestressing.
  • Demonstrated reduced material consumption compared to conventional methods.
  • Showed increased durability of the spun reinforced concrete structure.
  • Provided expressions for calculating rational bending moments and structural parameters effectively.

Abstract

Recently, due to the expansion of telecommunication and power networks, as well as other structures, the demand for designing efficient and durable tall supporting columns has increased. Efficient steel columns are well known, including prestressed stayed beam–column systems. However, because of their relatively high cost, designers often turn to reinforced concrete structures, which are not only relatively cheaper but also sufficiently strong and resistant to aggressive external influences. Nevertheless, the large self-weight of reinforced concrete structures and considerable material consumption encourage the search for new efficient solutions. One such solution is the use of spun reinforced concrete structures. Compared to conventional reinforced concrete structures, these solutions not only reduce material consumption but also increase durability. This study examines an innovative prestressed stayed beam–column structure consisting of a spun reinforced concrete core and supporting prestressed steel tension ties. The behavior of such a composite structure is analyzed, and calculations of internal forces and displacements are presented. The rational parameters of the composing elements of this new prestressed stayed beam–column structure are discussed, and their influence on the stress–strain state of the structure is evaluated. Expressions are provided for calculating the rational bending moments of the spun reinforced concrete core. The obtained solutions make it possible to select rational cross-sections of the core and ties, as well as the required prestressing of the tension ties, without iterative calculations.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Indriūnas et al. (2026) studied this question.

synapsesocial.com/papers/6994058c4e9c9e835dfd6822https://doi.org/10.3390/buildings16040793
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Finite element analysis of concrete‐encased columns reinforced with multiple steel sections2024
  2. 2Development of a Precast Column Solution Using Precast Prestressed Concrete Piles Filled with Cast-In-Place Concrete2026
  3. 3Performance Study on a New Type of Connection Joint for Prefabricated Stiffened Column and Composite Beam Frame Structures2026 · 1 citations
  4. 4Axial compressive performance and load‐carrying capacity of hybrid reinforced concrete columns with a built‐in spiral stirrup core2026
  5. 5Stiffened T-Shape Concrete Filled Tubular Tall Columns Axial-Bending Interaction2024