PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
February 19, 20260 citations

The Effect of Different Service Loads on the Behavior of Full-Scale Precast Concrete Sandwich Panels

View Full Paper
KAKhaldoon S. A. AltameemiOCOmar M. H. Chlaibawi

Key Points

  • This research aims to evaluate the performance of precast concrete sandwich panels under different service loads to assess their suitability for lightweight applications.
  • Developed low-cost precast concrete sandwich panel mixtures for light-weight applications.
  • Conducted five major flexural tests on full-scale panels under graduated loads.
  • Each panel designed with reinforced layers and insulation using expanded polystyrene.
  • Vertical deflections increased significantly with higher loads, showing near-linear behavior initially.
  • Flexural cracks began to develop at higher load limits.
  • Mesh connectors effectively maintained composite behavior under intermediate loads, but performance decreased at the highest load (1000 kg).

Abstract

This research aims to develop low-cost and light-weight precast concrete sandwich panels (PCSPs) suitable for the limited loads they may be applied in the future applications, such as lightweight roofing panels. The mixture of concrete was designed to accomplish light weight and ease of workability. Self-compacting concrete (SCC) was used, containing 850 kg/mm of sand and 500 kg/m3 of cement at a water-to-cement ratio of 0.35, with the addition of a superplasticizer at 1% by weight of cement. A full-scale panel was examined with dimensions of 4.5 m length , 1 m in width and thickness of 0.13m The bottom layer of PCSP reinforced with a 2.15 mm steel mesh with 32 × 32 mm openings, the top layer reinforced with chicken wire, and the insulation layer made of expanded polystyrene (EPS) insulation. The two concrete layers were connected using 1.47 mm diameter steel mesh shear connectors grids distributed in five locations along the specimen to ensure composite bonding between the layers. Five major flexural tests were conducted on the panels under graded loads of 250 kg stimulation to examine the behavior of the panel to withstand dead loads, 100 kg, 200 kg of person's weights and 1000 kg to represent different loading levels. Vertical displacements were measured using LVDTs located at specific positions along the specimen span. The results showed that increasing the load resulted in a significant increase in vertical deflections with near-linear behavior up to certain load limits. Then, flexural failure features (cracks) began to appear. The results also established that the mesh connectors performed effectively in maintaining composite behavior up to intermediate loading levels, while the degree of bonding decreased at higher loads (1000 kg). The study shows that the proposed structural system has acceptable proficiency for limited load bearing, with high light weight, making it suitable for economical precast roof applications in low-cost buildings.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Altameemi et al. (2026) studied this question.

synapsesocial.com/papers/6996a898ecb39a600b3ef822https://doi.org/10.1051/e3sconf/202669401008/pdf
Ask AI
Helpful
Bookmark
Share
View Full Paper