February 21, 2026Odontology0 citationsOpen Access

In vitro assessment of the role of air spray on pulp temperature changes for preheated resin composite Class V restorations in lower incisor

VOVinicius Borges OliveiraJGJuliana Anany Gonzales GuarneriMMMilena Ferreira Machado

Key Points

  • The study aims to evaluate how different air spray pressures affect pulp temperature during light-curing of preheated resin composites in lower incisors.
  • In vitro design with ethical approval
  • Class V cavity prepared in lower incisors
  • Thermocouple used to measure pulp temperature
  • Air spray applied at 15 and 30 psi during light-curing
  • Data analyzed using nonparametric mixed ANOVA and two-way ANOVA
  • Light-curing preheated resin composites increased pulp temperature to 42.5 °C
  • Air spray at 15 psi reduced pulp temperature to 28.4 °C
  • Air spray at 30 psi reduced pulp temperature to 26.8 °C
  • Vickers hardness of the restorations was not significantly affected

Abstract

Abstract To evaluate the effect of 15- and 30-psi air spray on in vitro pulp temperature (PT) during light-curing of buccal Class V restorations in lower incisors using preheated resin composites (RBCs). After ethical approval, a Class V cavity was prepared in a sound lower central incisor. A T-type thermocouple was inserted into the pulp chamber and connected to a temperature measurement system (Thermes WiFi, Physitemp). Simulated pulpal fluid flow was maintained at a rate of 0.001 mL/min. Real-time PT and working time were recorded during restoration with Viscalor Bulk-fill (VOCO) and Filtek One Bulk-fill (Solventum) preheated to 68 °C. Air spray (15 or 30 psi) was directed to the lingual surface, starting 3 s before and maintained throughout light-curing ( n = 9). Vickers hardness (VHN) was measured at the middle and inner surfaces near the top and bottom of each specimen. PT and VHN data were analyzed using nonparametric mixed ANOVA, and working time was analyzed using nonparametric two-way ANOVA, both followed by Bonferroni’s post hoc tests ( α = 0.05). Light-curing of preheated RBCs significantly increased PT (42.5 ± 1.3 °C; p < 0.001). Air spray at 15 and 30 psi reduced PT values (28.4 ± 1.3 °C and 26.8 ± 1.8 °C, respectively; p < 0.001) without affecting VHN values. Air spray during light-curing effectively minimized pulp temperature rise during restorative procedures using preheated RBCs on lower incisors.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Oliveira et al. (2026) studied this question.

synapsesocial.com/papers/69994cdf873532290d021c2ahttps://doi.org/10.1007/s10266-026-01324-4
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Effect of preheating on the viscosity of composite resins2024 · 16 citations
  2. 2Material-Dependent Microhardness Response to Preheating in Nanoparticulate Composite Resins Cured with High-Intensity Light2025 · 2 citations
  3. 3Hemodynamic regulation of the dental pulp in a low compliance environment1989 · 45 citations
  4. 4Monomer Conversion of Pre-heated Composite2005 · 329 citations
  5. 5A method of measuring the volume of human dental pulp cavities1986 · 33 citations