PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
February 25, 20260 citationsOpen Access

Alignment of in vitro and in vivo pulmonary inflammation models using crystalline quartz silica.

View Full Paper
ILIsidora LoncarevicUniversity of FribourgSMSeyran MutluUniversity of BernMDMartina DzepicUniversity of Bern

Key Points

  • The study aims to compare inflammatory responses in established in vitro and in vivo models after exposure to crystalline quartz silica.
  • Compared inflammatory endpoints between in vitro and in vivo pulmonary models following crystalline quartz silica exposure.
  • Extended in vitro assessment from 24 hours to 7 days to match OECD inhalation testing guidelines.
  • Employed a co-culture model with human bronchial cells and macrophages for exposure testing.
  • No increased cytotoxicity or barrier impairment was observed in vitro after 7 days.
  • Clear tissue damage was detected in vivo following exposure.
  • Increased release of interleukin-6 and IL-8 was measured at protein and gene levels.
  • Positive correlations were found in gene expression of IL-1β, IL-6, and IL-8 between models.

Abstract

Background Systematic in vitro-in vivo comparisons are increasingly used to assess the relevance and predictivity of in vitro lung models for inhalation toxicology and regulatory risk assessment. Here, we compared inflammatory endpoints across established in vitro and in vivo pulmonary models following exposure to crystalline quartz silica particles (DQ12). To better align exposure timelines, in vitro responses assessed at 24 h were extended to 7 days, matching the post-exposure period recommended in OECD inhalation testing guidelines for animal testing. To test its potential and limitations, we utilized a harmonized in vitro co-culture model consisting of the human bronchial cell line Calu-3 and human monocyte-derived macrophages, which were exposed to DQ12 particles.Results No increased cytotoxicity or impairment of barrier integrity, as assessed by transepithelial electrical resistance (TEER) and tight junction protein 1 (TJP1) gene expression, was observed 7 days after exposure in vitro, in contrast to clear tissue damage detected in vivo. However, we observed increased release of interleukin (IL)-6 and IL-8, measured at both protein and gene levels. Gene expressions of IL-1β, IL-6, and IL-8 showed positive correlations between the in vitro and in vivo models.Conclusions By extending exposure duration and aligning time points, this study identified inflammatory biomarkers that correlate between an in vitro lung model and in vivo data. These findings demonstrate the value of refined in vitro models for assessing particle-induced lung inflammation and support their relevance for hazard assessment.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Loncarevic et al. (2026) studied this question.

synapsesocial.com/papers/699e9143f5123be5ed04ea36https://doi.org/10.48620/94827
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Alignment of in vitro and in vivo pulmonary inflammation models using crystalline quartz silica2026 · 2 citations
  2. 268 Advancing a human-relevant 3D lung co-culture model for predicting effects of inhaled particles2026
  3. 3D94-01 Modeling Acute Silica-induced Inflammation Using Precision-cut Lung Slices2026
  4. 486 Indoor dust-induced cytotoxicity in dynamic lung-on-chip: role of exposure duration and mechanical cues2026
  5. 5Pro-inflammatory and genotoxic responses by metal oxide nanomaterials in alveolar epithelial cells and macrophages in submerged condition and air-liquid interface: An in vitro-in vivo correlation study2024 · 15 citations