PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
February 25, 20260 citations

Kanal Eğiminin Ötesinde: Tekrarlanan Kullanımda Modern NiTi Sistemlerinin Performans ve Yapısal Bütünlüğünün Değerlendirilmesi

View Full Paper
EÖEmre ÖvsayAAAyfer AtavDPDuygu Mustafa Pamuk

Key Points

  • This study aimed to compare the shaping performance, apical transportation, and structural integrity of two NiTi rotary file systems after repeated use and sterilization.
  • Prepared sixty resin blocks with 45° curvature using either AF-R or PU instruments.
  • Divided each group into three subgroups based on number of uses and sterilizations.
  • Evaluated canal centering and transportation using digital overlays and ImageJ software.
  • Assessed file deformation and separation through stereomicroscopy.
  • Performed statistical analysis using Kruskal–Wallis and Bonferroni tests.
  • AF-R demonstrated superior canal centering (P = 0.008) and lower apical transportation (P = 0.004).
  • No file separations in the AF-R group while PU showed a 6.7% separation rate by the third cycle.
  • AF-R instruments maintained their shape and mechanical behavior after sterilization.

Abstract

Aim: In endodontic treatment, nickel-titanium (NiTi) instruments, revolutionized root canal instrumentation owing to their superior flexibility, resistance to torsional fatigue, and shape memory. Among contemporary NiTi systems, ProTaper Ultimate (PU) (Dentsply Sirona, Ballaigues, Switzerland) and Fanta AF Rising (AF-R) (Fanta Dental, Shanghai, China) are widely utilized, yet differ consid-erably in terms of their metallurgical composition, design, and clinical performance. Although both systems are commonly used in clinical practice, there is a paucity of comparative data evaluating their canal centering ability, apical transportation, post-sterilization performance, and structural integrity after multiple uses. This study aimed to compare the shaping performance, apical transportation, and structural integrity of two thermally treated NiTi rotary file systems (AF-R and PU) after repeated use and sterilization cycles in standardized simulated curved canals.Material and Methods: Sixty standardized resin blocks with 45° curvature were prepared using either AF-R or PU instruments. Each group was divided into 3 subgroups based on the number of uses and sterilizations (1st, 2nd, and 3rd cycle). Canal centering and transportation were evaluated at 5 reference levels using high-resolution digital overlays and ImageJ software. File deformation and separation were assessed under stereomicroscopy. Statistical analysis was performed using the Kruskal–Wallis and Bonferroni tests, with P < 0.05 considered statistically significant.Results: AF-R demonstrated significantly superior canal centering (P = 0.008) and lower apical transportation (P = 0.004) across all refer- ence levels and usage cycles. No file separations occurred in the AF-R group, whereas PU exhibited progressive deformation and a 6.7% separation rate by the third cycle. AF-R instruments retained their original shape and mechanical behavior after autoclave sterilization.Conclusion: AF-R exhibited enhanced shaping precision, structural durability, and resistance to apical transportation compared to PU, especially after multiple clinical uses and sterilization. These findings support its suitability for minimally invasive and cost-effec- tive endodontic practice, particularly in anatomically complex canals.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Övsay et al. (2025) studied this question.

synapsesocial.com/papers/699e91d7f5123be5ed04f9cdhttps://doi.org/10.37990/medr.1705898
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1A Comparative Evaluation of the Cyclic Fatigue Resistance of Three Nickel-Titanium Rotary File Systems in a Simulated Curved Canal: An In Vitro Study2026
  2. 2Shaping Ability of Mtwo, ZenFlex, E-FLEX ONE, and E-FLEX EDGE Nickel–Titanium Rotary Instruments in Curved Root Canals: A Micro-Computed Tomography Study2026
  3. 3Evaluation of operator experience and nickel–titanium retreatment file systems in curved root canals2026
  4. 4Mechanical properties and micro-CT-based biomechanical performance of NiTi instrumentation systems in mandibular molars2026