February 25, 2026Journal of Thermoplastic Composite Materials0 citations

Process monitoring for overmoulding using tool-mounted sensors combining infrared temperature and piezoelectric pressure measurement: Validation and application to PP-GF and PPS-CF

View Full Paper
EKEike KrullPSPatrick SchiebelMPMichael P. Petrich

Key Points

  • This research aims to develop a novel in situ monitoring approach for overmoulding with improved bond strength in thermoplastics.
  • Developed tool-mounted sensors combining infrared temperature and piezoelectric pressure measurements
  • Conducted a full-factorial parametric study using rib-on-plate specimens
  • Performed rib-pull-off tests to measure interfacial bond strength
  • Designed and tested a V-shaped demonstrator geometry to analyze mechanical performance
  • Evaluated the functionality of sensors with short carbon fibre reinforced polyphenylene sulfide (PPS-CF)
  • Identified key process parameters: melt temperature, laminate surface temperature, cavity pressure, and local filling velocity
  • Higher thermal input and faster filling resulted in improved bond strength
  • Sensor data were repeatable, enabling correlation with mechanical joint performance
  • Demonstrated functionality of sensor systems at higher temperatures suitable for PPS-CF.

Abstract

An in situ process monitoring approach for overmoulding of short glass fibre reinforced thermoplastics onto continuous fibre laminates is presented. The approach is based on novel tool-mounted sensors that combine infrared (IR)-based temperature with piezoelectric pressure measurement. Applying the sensors, parameter studies are performed with the target to investigate influences on the interfacial bond strength of short-glass fibre reinforced polypropylene (PP-GF) on corresponding laminates. In a first step, a full-factorial parametric study with rib-on-plate specimens was performed to identify process parameters significantly affecting interfacial bond strength, which was measured by rib-pull-off tests. These were found to be the melt temperature, the laminate surface temperature, the cavity pressure and the local filling velocity. A second study focused on these parameters, and applied a V-shaped demonstrator geometry with a rib connecting both flanges. Mechanical performance was determined, by pulling on the flanges of the V-structure thereby causing joint failure. For both geometries the in situ sensor data proved highly repeatable and enabled direct correlation of the investigated parameters with the mechanical joint performance. The results show that both higher thermal input and faster filling improve the bond strength. In a further study the V-structures were manufactured with short carbon fibre reinforced polyphenylene sulfide (PPS-CF), thereby showing functionality of the sensors also for these higher temperatures. Overall, the study demonstrates that the novel integrated IR/pressure sensor systems enable reliable cavity-level process monitoring and provide a robust foundation for data-driven quality assessment in thermoplastic composite overmoulding.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Krull et al. (2026) studied this question.

synapsesocial.com/papers/699e91eaf5123be5ed04fccahttps://doi.org/10.1177/08927057261427429