February 26, 2026BMC Oral Health0 citationsOpen Access

Correlation between insertion torque value and bone density in D3 and D4 bone following photobiomodulation: a randomised interventional study

View Full Paper
ASAshika SinghaniaABAnjali BorleSGS. R. Godbole

Key Points

  • To assess the correlation between insertion torque values and bone density after photobiomodulation therapy.
  • Randomised interventional study involving 108 partially edentulous patients
  • Participants divided into six groups based on therapy type and bone classification
  • Insertion torque values recorded during implant placement and bone density assessed via CBCT.
  • Significant positive correlations between bone density and insertion torque in cervical, middle, and apical regions
  • Spearman’s rho ≥ 0.951, p < 0.01 indicating strong correlation
  • CBCT proven to be a predictive tool for implant stability after PBM therapy.

Abstract

This study aimed to assess the correlation between insertion torque values and bone density measured via CBCT in D3 and D4 bone types after photobiomodulation (PBM) therapy. 108 partially edentulous patients were divided into six groups based on PBM therapy type and bone classification. Insertion torque values were recorded during implant placement, and bone density was assessed via CBCT. Statistically significant positive correlations were observed between bone density and insertion torque in all regions (cervical, middle, apical) for both D3 and D4 bone types (Spearman’s rho ≥ 0.951, p < 0.01). Bone density correlates strongly with insertion torque values in both D3 and D4 bone following PBM therapy, suggesting its potential predictive value for implant primary stability. With the findings of the study, CBCT can be used as a predictive tool for assessing the implant stability and also advocates the use of PBM as an adjunct to improve primary implant stability. CTRI/2022/04/042033 dated 8/02/2022.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Singhania et al. (2026) studied this question.

synapsesocial.com/papers/699f95ba1bc9fecf3dab3d7fhttps://doi.org/10.1186/s12903-026-07875-w
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Effect of Photobiomodulation on Crestal Bone Density Around Dental Implants: A Case Report2024 · 1 citations
  2. 2Relationship between implant stability measurements obtained by insertion torque and resonance frequency analysis: A systematic review2017 · 148 citations
  3. 3Effectiveness of Photobiomodulation With Low-Level Laser Therapy on the Implant Stability Quotient at Different Time Intervals: A Randomized Clinical Trial2024 · 14 citations
  4. 4Evaluation of relationship between preoperative bone density values derived from cone beam computed tomography and implant stability parameters: a clinical study2013 · 81 citations
  5. 5An Overview of Implant Stability Measurement2018 · 12 citations