配管脈動による遠心圧縮機の振動

View Full Paper
豊倉豊 倉敷秀吉秀則 吉田潤林潤 林田

Key Points

  • The aim is to investigate the cause of asynchronous vibration in a centrifugal compressor during factory load tests.
  • Expanded investigation to include piping components.
  • Swapped positions of resistance orifice and valve.
  • Conducted vibration measurements before and after adjustments.
  • Asynchronous amplitude significantly decreased after modifications.
  • Vibration issues resolved, confirming piping's role in the problem.

Abstract

遠心圧縮機の工場負荷試験中に、非同期振動が発生。実績から、この振動が圧縮機本体に起因しているとは考えられないため、調査の対象を試験配管まで拡大。抵抗オリフィスとバルブの位置を入れ替えた結果、非同期振幅は大幅に低下し、問題は解決した。