Characterization of Reentrant Circuit in Macroreentrant Right Atrial Tachycardia After Surgical Repair of Congenital Heart Disease

View Full Paper
HNHiroshi NakagawaNSNayyar ShahKMKagari Matsudaira

Key Points

  • This research aims to characterize the reentrant circuits involved in macroreentrant right atrial tachycardia after surgical repair of congenital heart disease.
  • Identified channels formed by two or more scars within low voltage areas.

Structured PICO

Does ablation within narrow channels eliminate macroreentrant right atrial tachycardia in patients after surgical repair of congenital heart disease?

P
Population
Patients with macroreentrant right atrial tachycardia (MacroAT) after surgical repair of congenital heart disease (SR-CHD)
I
Intervention
Ablation within narrow channels formed by scars
O
Outcome
Elimination of MacroATsurrogate

Ablation targeting narrow channels formed by scars in areas of low voltage effectively eliminates macroreentrant right atrial tachycardia in patients with prior surgical repair of congenital heart disease.

Abstract

Abstract: Background —The purpose of this study was to characterize the circuit of macroreentrant right atrial tachycardia (MacroAT) in patients after surgical repair of congenital heart disease (SR-CHD). Methods and Results —Sixteen patients with atrial tachycardia (AT) after SR-CHD were studied (atrial septal defect in 6, tetralogy of Fallot in 4, and Fontan procedure in 6). Electroanatomic right atrial maps were obtained during 15 MacroATs in 13 patients, focal AT in 1 patient, and atrial pacing in 2 patients without stable AT. A large area of low bipolar voltage (≤0.5 mV) involved most of the free wall in all patients and contained 2 to 7 dense scars or lines of double potentials, forming 29 narrow channels (width ≤2.7 cm) between scars in all but 1 patient, who had a single scar and only focal AT. All 15 MacroATs were propagated through narrow channels. Ablation within the channel eliminated all 15 MacroATs with 1 to 3 (median 1) radiofrequency applications. Ablation was performed in 9 other channels identified during MacroAT (5 patients) and in 5 channels identified during atrial pacing (2 patients). Conduction block was obtained across 28 of 29 channels. After ablation, reproducible sustained right AT was not induced in any patient. During follow-up (median 13.5 months), new MacroATs, atrial fibrillation, or palpitations occurred in 3 of 16 patients. Conclusions —MacroAT after SR-CHD requires a large area of low voltage containing ≥2 scars forming narrow channels. Ablation within the channels eliminates MacroAT.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Nakagawa et al. (2001) studied this question.

synapsesocial.com/papers/69a1ab35e9cd91cb81c309b2https://doi.org/10.1161/01.cir.103.5.699
Ask AI
Helpful
Bookmark
Share
View Full Paper