PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
February 28, 2026Veterinary Sciences0 citationsOpen Access

Multiplex One-Step qPCR/RT-qPCR Assays for Detection of Ectromelia Virus, Murine Hepatitis Virus, Reovirus Type 3, and Parvoviruses

WLWenxin LuoXLXiaodong LiYZYuewei Zhang

Key Points

  • The research aims to create a rapid and accurate detection method for key viral pathogens in laboratory mice.
  • Developed a one-step multiplex real-time PCR detection method.
  • Simultaneously detected four viral pathogens without cross-reactivity.
  • Tested 128 suspected diseased mouse tissue samples for evaluation.
  • Assessed sensitivity, specificity, and reproducibility of the method.
  • The new method demonstrated higher sensitivity and specificity compared to ordinary PCR.
  • Detection limits were 1.08 × 10^1 copies/μL for ECTV, 1.14 × 10^1 copies/μL for MHV, and 2.38 × 10^1 copies/μL for MUV.
  • Reproducibility coefficient of variation was below 1.5%.
  • Showed strong linear correlation (R2 > 0.996) and amplification efficiency between 90% and 100%.

Abstract

The use of experimental animals with unified quality standards is an important condition for ensuring the effectiveness of scientific research. Ectromelia virus (ECTV), murine hepatitis virus (MHV), reovirus type 3 (Reo-3), and murine parvoviruses (MUV) are the four pathogens that need to be eliminated from SPF (Specific Pathogen-Free) level mice. These four pathogens present fast transmission and high pathogenicity, making it difficult to control. The previously described detection methods present substantial limitations in efficiency and accuracy. Thus, there is an urgent need for rapid and precise diagnostic methods to improve prevention and diagnosis efforts. In this study, we developed a one-step multiplex real-time PCR (mrt-PCR) detection method that can simultaneously detect four key viral pathogens causing diseases in laboratory mice without cross-reactivity with other mouse susceptible pathogens. We tested 128 suspected diseased mouse tissue samples collected from Beijing, and the results showed that this new method has higher sensitivity and specificity than ordinary PCR. The detection limit for ECTV, MHV, and MUV was determined to be 1.08 × 101 copies/μL, 1.14 × 101 copies/μL, 2.38 ×101 copies/μL, and 1.08 × 101 copies/μL, respectively. In addition, the assay showed excellent reproducibility, with a coefficient of variation below 1.5%, strong linear correlation (R2 > 0.996), and amplification efficiency between 90% and 100%. In summary, the mrt-PCR serves not only as a rapid and accurate detection and early prevention method for laboratory mice but also constitutes a robust tool for microbial quality control in laboratory mice.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Luo et al. (2026) studied this question.

synapsesocial.com/papers/69a286370a974eb0d3c00fcfhttps://doi.org/10.3390/vetsci13030217
Ask AI
Helpful
Bookmark
Share
View Full Paper