PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
February 28, 2026Research in Veterinary Science0 citationsOpen Access

A field-ready colourimetric LAMP assay for detection of Mycoplasma gallisepticum using rapid DNA extraction

View Full Paper
RMRebecca MayneSPSameer D. PantJHJiongrui Huang

Key Points

  • The aim is to develop an easy-to-use LAMP assay for detecting Mycoplasma gallisepticum with a rapid DNA extraction method suitable for field use.
  • Developed a Loop Mediated Isothermal Amplification (LAMP) assay for MG detection.
  • Compared LAMP performance with a conventional PCR assay using various sample types.
  • Utilized different DNA extraction methods including commercial kits and Ly 14 buffer with Chelex 100.
  • LAMP assay showed 100% agreement with PCR results for tracheal swabs.
  • Achieved 100% specificity against 13 non-target bacterial species.
  • Detection limits were 1 pg/μl for PCR and 10 pg/μl for LAMP, demonstrating high sensitivity and accuracy.

Abstract

Mycoplasma gallisepticum (MG) is a major respiratory pathogen of poultry, and rapid point of care tests for routine on farm surveillance are currently unavailable. This study describes a user-friendly Loop Mediated Isothermal Amplification (LAMP) assay for detecting MG, used together with a rapid DNA extraction method that supports field deployment. The performance of the LAMP assay was compared with a conventional PCR assay using three sample sets, including MG cultures, tracheal swabs from vaccinated and unvaccinated chickens, and cloacal swabs from turkeys. DNA was extracted using a commercial kit, Ly 14 buffer, or Ly 14 buffer combined with Chelex 100. A positive LAMP result was based on a clear colour change from red to yellow. The LAMP assay detected MG in tracheal swabs with 100% agreement with PCR and showed 100% specificity when tested against DNA from 13 non-target bacterial species. Cloacal swabs produced strong agreement between LAMP and PCR, particularly when DNA templates were prepared using Ly 14 or Ly 14 plus Chelex 100 extraction procedures. When DNA was extracted using the commercial kit, minor discrepancies were noted, with the sensitivity, specificity, and accuracy of LAMP for detecting MG in cloacal samples being 100%, 97.4%, and 97.5%, respectively, when used with the rapid extraction method. The limit of detection was 1 pg/μl for PCR and 10 pg/μl for LAMP. Overall, the LAMP assay was simple to perform, produced rapid visual results, and demonstrated consistent diagnostic accuracy. • Field ready LAMP assay developed for Mycoplasma gallisepticum detection. • Single step rapid DNA extraction removes need for centrifuge or lab tools. • LAMP showed strong agreement with PCR across tested samples.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Mayne et al. (2026) studied this question.

synapsesocial.com/papers/69a286b80a974eb0d3c01ed0https://doi.org/10.1016/j.rvsc.2026.106119
Ask AI
Helpful
Bookmark
Share
View Full Paper