PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
February 28, 2026Endodontology0 citationsOpen Access

A novel noninvasive radiographic working length determination method – A randomized controlled clinical trial

View Full Paper
JMJoseph MinuASAnand V. SusilaAVAruna Kumari Veronica

Key Points

  • The research aims to compare a new noninvasive radiographic method with an electronic apex locator for determining working length in root canals.
  • Conducted a randomized controlled trial with 208 root canals from 64 adults.
  • Used a geometric technique with a custom holder and digital protractor to standardize angulation.
  • Compared outcomes of the digital radiographic method and a fourth-generation electronic apex locator.
  • Followed the Consolidated Standards of Reporting Trials guidelines for analysis.
  • EAL group showed significantly lower underestimation (1.7%) compared to the DR group (15.1%).
  • Both methods had adequate master cone and obturation lengths; DR had one instance of overestimation (1.07%).
  • EAL had higher accuracy (61.7%) versus DR.
  • DR method led to a greater mean lesion size reduction (77%) compared to EAL (23%).

Abstract

Aim: This randomized controlled clinical trial compared a novel, noninvasive radiographic method with a fourth-generation electronic apex locator (EAL) for working length determination. Methods: A geometric technique using the law of symmetric triangles was piloted on extracted teeth and applied clinically with a custom sensor holder and digital protractor to standardize angulation. The trial followed Consolidated Standards of Reporting Trials 2025 Guidelines (CTRI/2020/01/022629). A total of 208 root canals from 64 adult patients were randomly assigned into two groups: Digital radiographic (DR) method ( n = 93 canals, 30 patients) and EAL (Root ZX Mini; n = 115 canals, 34 patients). The primary outcome was radiographic master cone fit within ± 2 mm of the apex. The secondary outcomes included obturation length, postoperative symptoms, and lesion healing using the Periapical Index at a 3-month follow-up. Analysis was performed using the SPSS v23.0 ( P < 0.05). Results: Underestimation was significantly lower in the EAL group (1.7%) than in the DR group (15.1%) ( P = 0.0001). Both showed adequate master cone and obturation lengths, with a single overestimation in the DR group (1.07%, P = 0.447). EAL had higher accuracy (61.7%, P = 0.0001), while DR achieved a greater mean lesion size reduction (77% vs. 23%, P = 0.04). Conclusion: Digital radiography showed a similar tendency to underestimate working length as the EAL, with a comparable need for correction. However, it yielded accurate measurements in only about half the cases. Importantly, it achieved significantly greater lesion size reduction. Although less precise, it remains a viable and low-radiation alternative in settings lacking access to EALs.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Minu et al. (2026) studied this question.

synapsesocial.com/papers/69a287130a974eb0d3c02840https://doi.org/10.4103/endo.endo_187_25
Ask AI
Helpful
Bookmark
Share
View Full Paper