PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
March 2, 20260 citationsOpen Access

Efficient Interleaved Multi-Band Outer Volume Suppression for Highly Accelerated Simultaneous Multi-Slice Imaging of the Heart

View Full Paper
AAAyda AramiÖDÖmer Burak DemirelTKToygan Kılıç

Key Points

  • This work aimed to develop interleaved multi-band outer volume suppression pulses to improve cardiac MRI efficiency.
  • Constructed multi-band outer volume suppression pulses from slab-selective saturation pulses.
  • Tested various pulse shapes using Bloch simulation and phantom experiments.
  • Compared CINE and myocardial perfusion scans with and without MB-OVS pulses for artifact evaluation.
  • Amplitude-optimized sinc pulses showed the best suppression efficiency and minimal artifacts.
  • CINE imaging with 5-fold SMS-OVS acceleration achieved leakage-free quality, even with added acceleration.
  • 9-slice perfusion imaging maintained accurate contrast dynamics with 16-fold spatial-only acceleration.

Abstract

In this work, we aimed to develop and evaluate multi-band outer volume suppression pulses for increased acceleration rates in simultaneous multi-slice accelerated cardiac MRI. MB-OVS pulses were constructed from a multi-band combination of two slab-selective saturation pulses and tested for various pulse shapes using Bloch simulation and phantom experiment. The MB-OVS pulses were interleaved between imaging pulses to ensure homogeneous suppression throughout the cardiac cycle/imaging window in vivo. Simultaneous multi-slice (SMS) CINE and first-pass myocardial perfusion scans with and without the proposed MB-OVS pulses were compared in terms of residual artifacts at high acceleration rates. Among the tested pulses, both Bloch simulation and phantom experiments showed that amplitude-optimized sinc pulses provided the best trade-off in suppression efficiency, the required B1+, SAR, and slab profile. CINE imaging with 5-fold SMS-OVS acceleration significantly outperformed imaging without MB-OVS, maintaining leakage-free image quality, even when adding 2-fold in-plane acceleration. SMS-OVS also enabled perfusion imaging in 9 slices with 1.7 × 1.7 mm2 resolution, achieving a 16-fold spatial-only acceleration while ensuring accurate contrast dynamics without leakage artifacts. Interleaved MB-OVS modules enabled thorough leakage artifact suppression in cardiac SMS-accelerated CINE and perfusion imaging, particularly at high acceleration rates. The proposed approach may be promising for unlocking further acceleration potential of SMS in cardiac imaging.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Arami et al. (2026) studied this question.

synapsesocial.com/papers/69a52d9af1e85e5c73bf0a31https://doi.org/10.3390/bioengineering13030286
Ask AI
Helpful
Bookmark
Share
View Full Paper