March 3, 2026Energy Storage and Saving2 citationsOpen Access

Enhancing energy saving and carbon footprint reduction using PCM-based heat exchanger: a COMSOL simulation approach

View Full Paper
RPRajendra Kumar PrajapatiSLShiv LalNational Research Centre on Seed SpicesSMShanti Lal MeenaRajasthan Technical University

Key Points

  • Energy storage capacity was enhanced using phase change material (PCM), specifically n-octadecane, for better thermal energy efficiency.
  • Annual CO2 emissions were reduced by 13.53 kg using a single PCM capsule, while an array of 60 tubes cut emissions significantly more.
  • Modeling was carried out using COMSOL Multiphysics, focusing on optimizing heat exchanger geometry to achieve maximum energy efficiency.
  • Economic analysis illustrates project feasibility, with a net present value of US$5.91 and a payback period of 3.75 years.

Abstract

• Detailed study, previous work, future possibility of a heat exchanger to fulfill energy demand. • Modeling and study of novel geometry of heat exchanger using COMSOL Multiphysics • Energy storage analysis by varying geometry and boundary conditions. • Analysis of the optimum thickness of the inner copper tube. • Techno-Economic Analysis and Carbon Mitigation. The increasing energy consumption and greenhouse gas emissions are negatively affecting the environment, among which thermal comfort accounts for more than 40% of the total consumption in residential buildings. In this study, the energy storage capacity of the heat exchanger was enhanced by integrating a phase change material (PCM) (n-octadecane) for thermal energy storage. To this end, this study focuses on leveraging the high latent heat and appropriate melting point of n-octadecane for effective phase-change applications. . The geometry of the heat exchanger was also optimized to improve the liquid fraction and energy storage capacity. A COMSOL Multiphysics-based simulation model was employed to investigate and optimize the heat exchanger’s performance. The results show improved energy efficiency compared to traditional methods. For instance, a single PCM capsule (25 mm × 30 mm × 1, 000 mm) can achieve an annual CO 2 emission reduction of 13. 53 kg. Furthermore, scaling up to an array of 60 PCM tubes (each 2. 55 m long) are used in the heat exchanger leads to annual energy savings of 2, 074. 68 kWh, corresponding to reduction in CO 2, SO 2, and NO emissions of 2, 070. 53 kg, 16. 68 kg and 4. 42 kg, respectively. Economic analysis indicates the project's feasibility, with a net present value of US5. 91 and a payback period of 3. 75 years for a solar chimney integrated with PCM. In conclusion, heat exchangers based on n-octadecane PCM demonstrate significant potential as an efficient and reliable solution for thermal energy storage in building applications, contributing to a reduced carbon footprint.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Prajapati et al. (2026) studied this question.

synapsesocial.com/papers/69a76069c6e9836116a2d24dhttps://doi.org/10.1016/j.enss.2025.09.006
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Numerical study of a multiple-segment metal foam-PCM latent heat storage unit: Effect of porosity, pore density and location of heat source2019 · 285 citations
  2. 2Evaluation of Melting Mechanism and Natural Convection Effect in a Triplex Tube Heat Storage System with a Novel Fin Arrangement2022 · 63 citations
  3. 3Highly conductive solid-solid phase change composites and devices enhanced by aligned graphite networks for solar/electro-thermal energy storage2024 · 36 citations
  4. 4Simulation of a ventilated cavity to enhance the effectiveness of PCM wallboards for summer thermal comfort in buildings2013 · 102 citations
  5. 5Numerical investigation of free-cooling system using plate type PCM storage2013 · 94 citations