March 3, 2026Indian Journal of Ophthalmology - Case Reports0 citationsOpen Access

Extensive Descemet’s membrane detachment on ultra-widefield swept-source OCT

View Full Paper
MFMeiqi FanJMJinhong MaXinjiang Medical UniversityLML MaYuhuangding Hospital

Key Points

  • Visual acuity improved from counting fingers to 20/20 post-treatment, indicating effective intervention.
  • Ultra-widefield swept-source OCT revealed a significant detachment of Descemet’s membrane measuring 7849 µm in diameter.
  • Following intervention, corneal thickness decreased from 1011 µm to 512 µm, showing successful resolution of corneal edema.
  • The study highlights the potential of air descemetopexy to restore corneal clarity after Descemet’s membrane detachment.

Abstract

A 61-year-old female patient underwent cataract phacoemulsification and intraocular lens implantation in her left eye. During a follow-up examination 1 week postsurgery, significant corneal edema and extensive detachment of Descemet’s membrane (DM) were observed in the left eye. Ultra-widefield swept-source OCT (SS-OCT) revealed a corneal thickness of 1011 μm Fig. 1. Descemet’s membrane detachment (DMD) refers to the separation of the DM from the posterior stroma, resulting in fluid accumulation in the pre-Descemet’s space, which leads to stromal and epithelial edema and a consequent decrease in vision.1,2 Following air descemetopexy, the cornea cleared, and the DM separation line became clearly visible. The DM was fully reattached, and the corneal thickness decreased to 512 μm Fig. 1. One week post-treatment, the visual acuity in the left eye improved from counting fingers to 20/20 Fig. 2.Figure 1: Ultra-widefield SS-OCT revealed a significant detachment of DM, with a diameter of 7849 µm in the central region of the left eye. This detachment was associated with an increase in corneal thickness to 1011 µm, and the presence of epithelial blisters was notedFigure 2: The cornea was clear, the air was completely absorbed, and the DM separation line was clearly visible (yellow arrow) after 1 week of the air injection (our picture has been enlarged by 300%)Authors contributions Meiqi Fan: Conceptualization, Methodology, Writing - original draft. Jinhong Ma: Visualization and Manuscript editing.Lusheng Ma: Manuscript editing and manuscript review. Declaration of patient consent The authors certify that they have obtained all appropriate patient consent forms. In the form, the patient(s) has/have given their consent for their images and other clinical information to be reported in the journal. The patients understand that their names and initials will not be published, and due efforts will be made to conceal their identity, but anonymity cannot be guaranteed. Financial support and sponsorship: Nil. Conflicts of interest: There are no conflicts of interest.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Fan et al. (2026) studied this question.

synapsesocial.com/papers/69a7666dbadf0bb9e87dcf75https://doi.org/10.4103/ijo.ijo_1394_25