Negative Gaseous Ions in Positive-Voltage Electrospray Ionization Mass Spectrometry

View Full Paper
XWXing-Bo WangOOOchir OchirovBKBo-Cheng Ke

Key Points

  • The aim is to understand how negative ions can form during positive-voltage electrospray ionization mass spectrometry.
  • Measured spray current on a counter electrode with concentric conductive rings
  • Conducted mass spectrometry measurements in negative-ion mode
  • Compared MS intensities of positive and negative ions under different voltage conditions
  • Negative ions were detected in the charged aerosol from positive-voltage electrospray
  • The presence of nebulizing gas influences ion generation
  • Analyte structure impacts the ability to generate corresponding negative ions

Abstract

Here, we report a serendipitous observation of negative ions in positive-voltage electrospray ionization (ESI) mass spectrometry (MS). Several previous studies have demonstrated that electrospray operated with positive voltage can generate droplets carrying a negative net charge. Our spray current measurements on a counter electrode with concentric conductive rings indicate the presence of negative species within the charged aerosol produced by positive voltage electrospray. MS measurements performed in negative-ion mode captured negative ions generated by positive electrospray, both in the presence and absence of nebulizing gas. Analyte structure influences the ability of positive electrospray to generate the corresponding negative ions. The MS intensities produced by positive and negative ions were compared when positive and no voltage was applied to the electrospray. Possible mechanisms underlying these observations are discussed in the context of recent literature. These findings represent the first direct MS measurement of negative desolvated gaseous ions from standard positive electrosprays and provide new mechanistic insights that may inform future ESI development.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Wang et al. (2026) studied this question.

synapsesocial.com/papers/69a91dd2d6127c7a504c0f9chttps://doi.org/10.1021/acs.analchem.5c08108
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Spontaneous Recycling of Electrosprayed Sample by Retrograde Motion of Microdroplets2024 · 6 citations
  2. 2Mechanism of electrospray mass spectrometry. Electrospray as an electrolysis cell1991 · 357 citations
  3. 3The mean free path in air1988 · 395 citations
  4. 4Zero Volt Paper Spray Ionization and Its Mechanism2015 · 83 citations
  5. 5A deeper look into sonic spray ionization2014 · 24 citations