PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
March 6, 2026RMD Open0 citationsOpen Access

18 FFAPI PET/CT-based scoring systems for patient assessment in IgG4-related disease

View Full Paper
DCDonghe ChenDHDanqing HuangCSChuanyin Sun

Key Points

  • This research aims to define organ-specific reference thresholds and develop a scoring system for gauging disease activity in IgG4-RD.
  • Retrospective study of 85 patients with IgG4-RD and 10 healthy individuals.
  • Utilized [18F]FAPI PET/CT for imaging.
  • Defined organ-specific uptake thresholds based on healthy individual data.
  • Developed FPAS-IgG4 scoring system using logistic regression and ROC analysis.
  • 64 lesions biopsied from 85 patients were confirmed positive for IgG4 in 90.6% of cases.
  • FAPI PET/CT sensitivity, specificity, and accuracy were 86.2%, 83.3%, and 85.9% for detecting IgG4-RD.
  • Active disease group had an FPAS-IgG4 score of 5.2±3.0 compared to 1.7±1.3 in inactive disease (p<0.0001).
  • FPAS-IgG4 >2 distinguished active from inactive disease with 93.2% sensitivity and 73.1% specificity.

Abstract

Background 18 F-Fibroblast activation protein inhibitor ( 18 FFAPI) positron emission tomography (PET)/CT is an emerging tool for detecting IgG4-related disease (IgG4-RD). However, standardised quantitative analysis and image scoring present ongoing challenges in patients with IgG4-RD. Purpose To establish organ-specific reference thresholds for IgG4-RD involvement on 18 FFAPI PET/CT images, and to develop a novel, clinically applicable scoring system to monitor disease activity in patients with IgG4-RD. Methods This retrospective study recruited 85 patients with IgG4-RD and 10 healthy individuals, all of whom underwent 18 FFAPI PET/CT. Organ-specific uptake thresholds were defined as 18 FFAPI uptake greater than the maximal standardised uptake value +3 SD in the corresponding anatomical regions of healthy individuals. Moreover, we developed a novel method, 18 FFAPI PET/CT Activity Score of IgG4-RD (FPAS-IgG4), for scoring disease activity using a logistic regression model with receiver operating characteristics curve analysis. Results Among 85 patients with IgG4-RD, 64 lesions suspected of IgG4-RD involvement were biopsied and 58 (90.6%) of these lesions were positive for IgG4. 18 FFAPI PET/CT achieved a sensitivity, specificity and accuracy of 86.2%, 83.3% and 85.9%, respectively, for detecting IgG4-RD based on organ-specific uptake thresholds. The active disease group had a higher FPAS-IgG4 than the inactive disease group (5.2±3.0 vs 1.7±1.3, p2 showed a sensitivity of 93.2% and a specificity of 73.1% in distinguishing between active and inactive disease. Multivariable logistic regression analysis demonstrated that FPAS-IgG4 was strongly associated with active IgG4-RD (p=0.001). Conclusion 18 FFAPI PET/CT could be a valuable tool for monitoring the activity of IgG4-RD, aiding in disease stratification.