March 7, 2026Frontiers in Public Health0 citationsOpen Access

Energy consumption features, correlative factors, and management strategies of tertiary hospitals across various climate zones in Jiangsu, China

XNXiaolin NiYPYu PanLPLixin Peng

Key Points

  • This research aims to identify driving factors of energy consumption and explore energy-saving strategies in tertiary hospitals.
  • Combined quantitative and qualitative methods for data collection and analysis.
  • Conducted field surveys and distributed questionnaires in 12 tertiary general hospitals.
  • Analyzed building data and energy management information over a year.
  • Hospitals showed similar quarterly energy use patterns across climate zones.
  • Cold zone energy use was primarily influenced by operational scale.
  • Hot-summer-cold-winter zone energy use was affected by hospital size and external temperature.
  • All hospitals had energy-saving technologies, but none used real-time online energy monitoring systems.

Abstract

Introduction In line with China’s “Dual Carbon” goals, achieving a green transformation of the healthcare system is imperative. This study aims to identify the factors driving energy use and to explore energy-saving strategies in large tertiary general hospitals across various architectural climate zones, thereby providing insights for sustainable development within the healthcare sector. Methods Adopting a research design of “quantitative as the main approach, supplemented by qualitative” methods, we integrated data analysis, field surveys, and questionnaires. The study examined 12 tertiary general hospitals in Jiangsu Province from 2022 to 2023, collecting on-site building data and energy management information. Data analysis combined Spearman correlation analysis with findings from the questionnaire surveys. Results The analysis revealed that hospitals in different climate zones exhibited similar quarterly patterns of energy use, but the key correlative factors varied significantly. Specifically, energy consumption in cold zones was primarily affected by operational scale, whereas in hot-summer-cold-winter zones, it was influenced by both hospital size and external temperature. Field surveys indicated that although all sampled hospitals had implemented some energy-saving technologies and management systems, none had installed real-time online energy monitoring systems. Conclusion To establish efficient, low-carbon, and resilient hospitals, tailored strategies are recommended. For cold zones, the focus should be on optimizing energy structures, building design, and facility layout. For hot-summer-cold-winter zones, improving building insulation is crucial. Furthermore, accelerating investment in intelligent carbon-monitoring systems, managing energy hardware upgrades at the source, and enhancing staff energy-saving awareness are essential steps forward.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Ni et al. (2026) studied this question.

synapsesocial.com/papers/69abc0b85af8044f7a4e9599https://doi.org/10.3389/fpubh.2026.1750668
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Improving the Indoor Air Quality of Office Buildings in the Post-Pandemic Era—Impact on Energy Consumption and Costs2024 · 21 citations
  2. 2Optimizing air quality and health Co-benefits of mitigation technologies in China: An integrated assessment2024 · 9 citations
  3. 3Analyzing regional disparities and spatial distribution dynamics of energy consumption levels in China2024 · 3 citations
  4. 4Engineering Microgrids Amid the Evolving Electrical Distribution System2024 · 2 citations
  5. 5Handling uncertainty when performing economic evaluation of healthcare interventions.1999 · 390 citations