PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
March 7, 2026Case Studies in Thermal Engineering2 citationsOpen Access

Optimization of a latent heat thermal energy storage device for waste heat recovery in data center campus

View Full Paper
PLPin LiMCMiaopeng ChenSLSumei Liu

Key Points

  • The aim is to enhance the efficiency of latent heat thermal energy storage systems in data centers located in high-altitude regions.
  • Designed a latent heat thermal energy storage system integrated with photovoltaic power and waste heat.
  • Developed a validated 2D computational fluid dynamics model to simulate phase-change heat transfer.
  • Conducted multi-parameter optimization of heat transfer fluid tube characteristics.
  • Assessed economic viability by comparing investment payback periods of design configurations.
  • Eccentricity significantly affects storage efficiency, with 30 mm eccentricity reducing melting time by 27%.
  • Optimal configuration achieved a 62% increase in storage efficiency and a 34.5% reduction in melting time.
  • Economic analysis showed a 27% reduction in heat cost with a payback period of 1.3 years.

Abstract

Waste heat recovery is critical for improving data center (DC) energy efficiency, particularly in high-altitude regions such as the Qinghai Plateau. Here, the intermittency of solar energy disrupts thermal stability, while winter electric heating elevates carbon emissions. To address these challenges, a latent heat thermal energy storage (LHTES) system integrated with photovoltaic (PV) power and waste heat was designed specifically for DCs on the Qinghai Plateau. To enhance heat storage efficiency, a validated 2D computational fluid dynamics (CFD) model based on the enthalpy-porosity method was established to simulate the phase-change heat transfer process. Multi-parameter optimization of heat transfer fluid (HTF) tube diameter, eccentricity, and layout was then conducted using a robust orthogonal design. Economic viability was evaluated by comparing the investment payback periods of different design configurations. Key findings indicate that eccentricity exerts the most significant influence on heat storage efficiency. The case with a 30 mm eccentricity cuts melting time by 27% and increases heat storage efficiency by 44% via natural convection compared to the baseline. Notably, variations in tube diameter have negligible impact on heat storage capacity. The optimal HTF tube configuration was identified as 30 mm eccentricity, 15 mm diameter, and uniform layout. This configuration reduces melting time by 34.5%, increases storage efficiency by 62%, and improves total thermal capacity by 6%. Economically, the optimized system lowers the levelized heat cost by 27% with a short payback period of 1.3 years. These results demonstrate the feasibility of integrating LHTES systems with PV power and waste heat for DCs on the Qinghai Plateau.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Li et al. (2026) studied this question.

synapsesocial.com/papers/69abc1235af8044f7a4e9cf7https://doi.org/10.1016/j.csite.2026.107898
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1China's green data center development:Policies and carbon reduction technology path2023 · 83 citations
  2. 2Heat transfer enhancement of phase change materials using tree shaped fins: A comprehensive review2025 · 84 citations
  3. 3Experimental observations on the heat transfer enhancement caused by natural convection during melting of solid–liquid phase change materials (PCMs)2015 · 121 citations
  4. 4Natural Convection Effect on Solidification Enhancement in a Multi-Tube Latent Heat Storage System: Effect of Tubes’ Arrangement2021 · 25 citations
  5. 5A fixed grid numerical modelling methodology for convection-diffusion mushy region phase-change problems1987 · 2,654 citations