PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
March 8, 2026International Communications in Heat and Mass Transfer4 citationsOpen Access

Thermal performance evaluation of low-GWP refrigerant pairs in cascade refrigeration systems: An experimental and simulation study

View Full Paper
PKParthiban KasiVel Tech Rangarajan Dr. Sagunthala R&D Institute of Science and TechnologyASA. SathishkumarSRM Institute of Science and TechnologyMCMarimuthu CheralathanSRM Institute of Science and Technology

Key Points

  • This research investigates how low-global warming potential refrigerant pairs affect the performance of cascade refrigeration systems.
  • Conducted experimental measurements and steady-state simulations.
  • Evaluated refrigerant combinations in high-temperature and low-temperature circuits.
  • Analyzed the impact of evaporator and condenser temperatures on system efficiency and compressor work.
  • System COP decreases with higher condenser temperatures, ranging from 2.86 at 80°C to 2.34 at 130°C.
  • Increasing evaporator temperature improves LTC cooling capacity, enhancing overall system COP.
  • R515B-R472A refrigerant pair achieved the highest COP and lowest compressor work, with simulation results indicating values between 2.86–2.73.

Abstract

The thermodynamic performance of ultra-low-temperature vapor-compression cascade refrigeration systems (CRS) using low-global warming potential (GWP) refrigerants was systematically investigated through experimental measurements and steady-state simulation. The study evaluated various refrigerant combinations in the high-temperature circuit (HTC: R513A, R515B, R466A) and low-temperature circuit (LTC: R472A, R1150), focusing on the influence of evaporator and condenser temperatures on system efficiency, compressor work, and mass flow rates. Results show that system COP decreases with increasing condenser temperature, from 2.86 at 80 °C to 2.34 at 130 °C, due to higher HTC condensing pressures, elevated interstage temperatures, and increased total compression work. Conversely, increasing the evaporator temperature from −100 °C to −55 °C enhances LTC cooling capacity and reduces LTC compressor work, while slightly increasing HTC work, thereby improving overall system COP. Among the tested refrigerant pairs, R515B-R472A consistently achieved the highest COP (simulation: 2.86–2.73; experimental: 1.67–1.14) and lowest total compressor work (simulation: 3.50–3.61 kW; experimental: 1.62–2.00 kW), attributed to R472A's high latent heat and temperature glide, which improve cascade heat-exchanger matching, and R515B's moderate HTC discharge pressures. System energy consumption was also strongly affected by storage conditions, with low-load operation reducing LTC and HTC compressor work substantially. Simulation predictions closely captured experimental trends, with COP overestimated by 5–12% due to idealized assumptions, yet providing a reliable tool for parametric analysis and design optimization. The study demonstrates that optimal refrigerant pairing and precise thermal management can enhance CRS energy efficiency by up to 18% while minimizing environmental impact.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Kasi et al. (2026) studied this question.

synapsesocial.com/papers/69ada804bc08abd80d5bb316https://doi.org/10.1016/j.icheatmasstransfer.2026.110930
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Optimizing the refrigerants in ultra-low temperature Semiconductor processing chiller with mixed Refrigerant2024 · 7 citations
  2. 2Energy and environmental comparison of two-stage solutions for commercial refrigeration at low temperature: Fluids and systems2014 · 125 citations
  3. 3Experimental investigation on the performance and global environmental impact of a refrigeration system retrofitted with alternative refrigerants2016 · 60 citations
  4. 4A novel design of cascade neural networks for magnetized nanofluidic model in porous convergent–divergent channels2025 · 2 citations